666005
5
Zoom out
Zoom in
Vorherige Seite
1/29
Nächste Seite
Stay Mode
Input user code or admin code, and press [Stay Mode] key, the LED
indicator flashes once and the keypad beeps once and sends [Stay
Mode] command to the control panel.
When the alarm panel receives the signal, the siren will beep once
and the [Stay Mode] indicator will light on, the alarm system enters
stay mode state.
All the sensors in other zones are armed to prevent the intruder
except that the motion detector in Home Mode Zone is disarmed,
so that people can move freely at home.
Emergency Call
If not inputting code for SOS is set, user just holds the [SOS] key for
3 seconds, the LED indicator flashes once, the keypad beeps once,
and the control panel alarms immediately.
If inputting code for SOS is set, user needs input user code or
admin code before holding the [SOS] key for 3 seconds to send an
alarm.
Mute Mode
Mute mode means that the LED indicators of control panel flash,
but the siren does not beep, to avoid disturbing the neighborhood.
Input user code or admin code, and hold any key of [Arm] [Disarm]
[Stay Mode] for 2 seconds, the LED indicator flashes once, the
keypad beeps once and sends corresponding command to the
control panel.
When the alarm panel receives the signal, the LED indicator lights
on or off, but the siren does not beep.
Notices and Maintenance
In order to avoid any harm to the users or others during usage and
prolong the usage life, please abide by the following notices.
Usage Notices
General instruction
The keypad should be connected to control panel before use.
The power supply of keypad will probably impact on the
transmitting distance of wireless signal.
The keypad can be powered by 3 pcs of AAA batteries, or wired
by DC 12V.
The keypad is compatible for any our alarm system.
Please remove the battery insulating strip before use.
Do not press SOS key if there's no emergency to avoid disturbing
the neighborhood..
Check the keypad regularly to ensure the system works properly
in case of emergency.
The keypad is neither waterproof nor moisture-proof, please install
it in a shady, cool and dry place.
The case of keypad is made of ABS. Please keep it away from
strong light to ensure the lifetime..
Forbiddance
The keypad is non explosion-proof. Please keep it away from fire,
flame sources.
Install the keypad away from objects such as heater, air
conditioner, microwave oven etc. that produces heat or
electric-magnetic.
Forbiddance of decomposition
Take the keypad for disposal of recycling according to the local
regulation.
Do not take apart the product if you are not a professional
technician.
Maintenance
You can get most dust or fingerprint off with a dry, soft cloth or
tissue. If there is dirt on the keypad, please wipe the surface by a
soft cloth with a little dilute alkaline detergent and then wipe again
with a dry cloth.
FAQ
Problem Cause Solution
No response
from keypad
Low battery Please change the battery
The positive and
negative terminals
are reversed
Follow the right terminal
direction and insert the battery
again
Keypad is locked by
inputting wrong
passcode continually
more than 6 times
Keypad will be unlocked after
non-operation for 20 seconds
Keypad
cannot
connect to
control panel
No response from
alarm panel
Make sure the alarm panel is
powered on
Make sure the alarm panel
enters learning state
Alarm panel beeps
twice
Keypad has been learned
No response
from the
control panel
by operating
on keypad
Keypad is not
learned to control
panel
Please connect the keypad to
the control panel by following
the manual instruction
Distance between
keypad and control
panel is too far
Please move the keypad in a
proper distance where control
panel can receive the signal of
keypad
It’s recommended to buy signal
repeater to extend the distance
Cannot
disarm by
RFID Tags
The RFID tags are
not learned to
keypad
Please connect the RFID tag to
control panel by following the
manual instruction
Disarm by RFID tag
function is
deactivated
Enter setup state and activate
the function of disarm by RFID
tag
Direct disarm by
RFID tag is disabled
Disarm after pressing [*] key
Keypad
cannot be
programmed
Keypad is not waked
up
Please input [admin code] + [#]
to wake up the keypad
Keypad doesn’t enter
setup state
Please input [admin code] +
[#], and press [3] to enter setup
state
Keypad
cannot be
armed,
disarmed and
in stay mode
Haven't input user
code or admin code
before operation
Please input the user code or
admin code before operation
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Chacon 34958 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info