UNPACKING THE STOVE
The stove arrives fixed its pallet facing up. There must be adequate
facilities for unloading and manoeuvring into position The wrapping
is first removed, then the stove released from the pallet by removing
the screws from the base. The stove may now be moved to its final
position. The pallet is intended to be cut up and used for kindling fuel.
HEALTH AND SAFETY PRECAUTIONS
Please take care when installing the stove that the requirements of
the Health and Safety at Work Act 1974 are met.
Some types of fire cement are caustic and should not be allowed to
come into contact with the skin. In case of contact wash with plenty
of water.
If there is a possibility of disturbing any asbestos in the course of
installation then please use appropriate protective equipment.
Ideally there should not be an extractor fan fitted in the same room
as the appliance. If this situation is unavoidable then specialist advice
should be taken to ensure that the extractor fan does not cause
the appliance to emit fumes into the room. An additional air supply
correctly positioned may be necessary. It is essential to carry out a
spillage test to ensure that the appliance can operate safely when the
extractor fan is operating.
There must be an adequate air supply into the room in which the
appliance is installed to provide combustion air. The combustion air
supply must be via a permanently open vent. The requirement for
minimum free area is partly dependent on the design air permeability
of the house. In older properties the air permeability will be above
5.0m³/(h.m²), but in some modern properties it may be less.
The vent must be positioned such that it is not liable to blockage.
Minimium areas are given in the following table:
This stove is capable of intermittent operation, and is not suitable for
use in a shared flue system.
In addition to these instructions the requirements of BS.8303 and
BSEN 15287-1:2007 must be fulfilled. Local Authority Bylaws
and Building Regulations, including those referring to national and
European Standards, regarding the installation of Solid Fuel burning
appliances, flues and chimneys must also be observed.
CO ALARMS
Building regulations require that whenever a new or replacement
fixed solid fuel or wood/biomass appliance is installed in a dwelling
a carbon monoxide alarm must be fitted in the same room as
the appliance. Further guidance on the installation of the carbon
monoxide alarm is available in BS EN 50292:2002 and from the
alarm manufacturer’s instructions. Provision of an alarm must not
be considered a substitute for either installing the appliance correctly
or ensuring regular servicing and maintenance of the appliance and
chimney system.
SPECIFICATION
CHIMNEY
In order for the appliance to perform satisfactorily the chimney
height must not be less than 4 metres measured vertically from the
outlet of the stove to the top of the chimney. The internal dimensions
of the chimney should preferably be 150-200 mm (6”- 8”) either
square or round and MUST NOT BE LESS THAN 125 mm (5”)
If an existing chimney is to be used it must be swept and checked,
it must be in good condition, free from cracks and blockages, and
SPECIFICATION COUNTRY 4 BLU
Fuel Wood logs
Rated Heat Output kW (BTU/hr) 5.0
Stove Weight kg (Packed) 60kg
Flue Temperature °C 221
Minimum Flue Draught 12Pa
Flue gas Mass Flow g/s 4.5
Hearth Temperature >100
Minimum distance from
combustibles mm SIDE BACK
Without optional heat shield 480 550
With optional heat shield 480 150
The outputs in the table are based on a 45 minute re-fuelling cycle
burning seasoned hardwood logs. All tests are carried out in accordance
with BSEN 13240.
AIR PERMEABILITY
m3/(h.m2)
MINIMUM VENT AREA
cm2(in2)
COUNTRY 4 BLU
>5.0 No requirement
<5.0 27.5 (4.3)
INSTALLATION INSTRUCTIONS
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Charnwood Country 4 Blu wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info