Gravity Return 28mm
Gravity Flow 28mm
22mm Open Vents
Cold Water Tank
Overflow
Domestic Hot Water Draw Off
Drain Cock
Indirect Hot Water Cylinder
Central
Heating Flow
Circulating Pump
Central
Heating
Return
Drain Cock at Lowest Point
Minimum Return
Thermostat
Gravity Radiator
Overflow
Feed and Expansion Tank
A
B
The shaded area on the face of
the surrond is the minimum flat
area required.
750mm
660mm
Dim.A:
Max. 470mm (18-1/2")
Min.405mm (16")
Dim.B:
Max. 575 (22-2/3")
Min. 555mm (21-3/4")
If the system is to be a combined heating and domestic hot
water system then a double feed indirect hot water storage
cylinder to BS:1566 part 1 should be used. In order to prevent
the build up of scale and corrosion a suitable inhibitor should
be used. The system must be correctly vented as shown in
Figs. 8 and 9. The height differential between the header tank
and the appliance must not exceed 15.2 metres (50 feet).
If all four boiler tappings are used then, if possible, diagonal
pairs should be connected for domestic hot water and central
heating. Where a common return is used an injector tee must
be incorporated into the system as shown in Fig. 9. This will
ensure that a good domestic hot water supply is maintained
when the central heating pump is operating.
The system must incorporate a gravity circuit which will
normally heat the domestic hot water and an unvalved
radiator with an output of at least 0.75 kW. When the
appliance is not connected to a domestic hot water system the
unvalved radiator(s) on the gravity circuit must have an output
of at least 1.0 kW. This is to prevent boiling in case of pump
failure.
If the boiler reduction brick is fitted then the appliance may be
used for room heating and supplying domestic hot water
without the need for a gravity radiator.
All pipework in the primary circuit must be 28 mm diameter
and the gravity flow pipe must rise continuously from the
boiler to the open vent. Two typical systems are shown in
Figures 8. and 9.
If the fire is used to heat a small central heating system then
the heat output to the room from the fire will be reduced.
Fig. 5. shows the ratio of space heating to water heating
which can be expected.
SYSTEM CONTROLS
The circulating pump may be controlled by means of time
switches, room thermostats or outdoor thermostats.
Radiators may be either manually or thermostatically
controlled. These controls will all work in conjunction with
the thermostat on the appliance and the minimum return
thermostat.
We recommend fitting a pipe thermostat onto the gravity
return and wiring it into the mains supply to the pump so that
if the gravity return temperature drops below 45° C then the
pump will cut out. This will help to prevent condensation
forming on the boiler faces and will thereby increase the life
of the boiler. Use of a minimum return thermostat also
ensures that priority is given to the domestic hot water. These
thermostats are available from ourselves if you are unable to
obtain them locally.
®
INSTALLATION INSTRUCTIONS charnwood
11
Fig. 8 Typical Central Heating and Hot Water System Using 4
Boiler Tapping
Fig. 7. Limiting Dimensions of Surround and Opening
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Charnwood LA 30iB wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info