815487
7
Zoom out
Zoom in
Vorherige Seite
1/16
Nächste Seite
instructions with regard to sweeping should be consulted.
Check that:
a) the air inlet is not obstructed in any way,
b) that chimneys and flueways are clear,
c) that a suitable fuel is being used,
d) that there is an adequate air supply into the room,
e) that an extractor fan is not fitted in the same room as the
fire.
Check that:
a) the doors are tightly closed,
b) the thermostat knob is turned down to the minimum
setting,
c) the air inlet damper is closed (at the bottom left of the
appliance), and that it is not prevented from closing
completely by a piece of ash,
d) a suitable fuel is being used,
e) the door seals are in good condition.
If the fire is over-fired it will cause premature failure of the
internal fire parts. Overfiring is occurring when any internal
parts of the fire begin to glow red. To prevent over-firing
ensure that:
a) the door seals are kept in good condition, and that the
doors are sealing correctly,
b) the thermostat on the fire is working correctly,
c) a suitable fuel is being used.
Warning Note:
Properly installed and operated this appliance will not emit
fumes. Occasional fume from de-ashing and re-fuelling may
occur. Persistent fume emission is potentially dangerous and
must not be tolerated. If fume emission does persist then the
following immediate actions should be taken:
TROUBLE SHOOTING
Fire Will Not Burn
Fire Blazing Out Of Control
Over-Firing
Fume Emission
such as WD40, will also help to keep all internal parts working
well.
After long periods where the fire has been out of use, the
chimney and appliance flueways should be cleaned before
lighting.
For the fire to operate correctly it is important that the door
seals are in good condition. Check that they do not become
worn or frayed and replace them when necessary.
It is recommended that the fire is serviced once a year to keep
it in first class working order. After cleaning out the firebox
thoroughly, check that all internal parts are in good working
order, replacing any parts that are beginning to show signs of
wear. Check that the doors seals are in good condition and
that the doors seal correctly. Check the operation of the
thermostat, both when cold and hot. A servicing guide, TIS
48. is available on request.
The chimney should be swept at least twice a year. In most
installations it will be possible to sweep the chimney through
the appliance.
First remove the front firebars and the throat plate. Then
sweep the chimney ensuring that soot is removed from all
horizontal surfaces after sweeping.
In situations where it is not possible to sweep through the
appliance the installer will have provided alternative means,
such as a soot door. After sweeping the chimney the appliance
flue outlet and the flue pipe connecting the appliance to the
chimney must be cleaned with a flue brush.
After clearing any soot from within the fire, replace the throat
plate and the front firebars.
Different types of sweep’s brushes are available to suit
different flueways. For standard brick chimneys a wire centre
sweep’s brush fitted with a guide wheel is recommended. For
prefabricated insulated chimneys the manufacturers
Door Seals
Servicing
CHIMNEY SWEEPING
7
®
OPERATING INSTRUCTIONS charnwood
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Charnwood LA20i wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info