815487
10
Zoom out
Zoom in
Vorherige Seite
1/16
Nächste Seite
10
PREPARATION OF FIREPLACE
FITTING THE FIRE
Before fitting the appliance into an existing fireplace remove
the fireback and any loose in-fill material.
The hearth, surround and opening for the appliance must
conform with Figs. 4 and 5. The flat area around the opening
must be a minimum of 750 mm wide and 660 mm high.
Ensure that the hearth and the base in the opening are flat,
level, and at right angles to the surround.
Make a hole in the front of the chimney breast to give access
for infilling and fixing the flue pipe. If the optional boiler is to
be fitted it will also be necessary to make a hole in the side of
the chimney breast to give access for the pipework.
In some cases it may be necessary to place the connecting flue
pipe in the chimney before fitting the fire into the fireplace.
Apply fire cement to the rear face of the sealing flange on the
appliance. Fit the appliance into the opening ensuring that it is
central and that a good seal is made between the sealing
flange and the face of the surround.
Remove any excess fire cement from around the sealing
flange.
The appliance should be screwed to the hearth through the
holes at the base of the sealing flange.
The optional add-in boiler which may be fitted in the
appliance has an output sufficient for domestic hot water
heating. If the boiler is fitted then the room heating will be
reduced.
The hot water system should be a gravity circuit and must be
correctly vented as shown in Fig. 6.
The steel boiler in conjunction with a double feed indirect hot
water storage cylinder to BS:1566 part 1 should be used in
most situations, unless the appliance is to be fitted in a soft
water area in which case the stainless steel boiler may be used
with a direct hot water cylinder.
All pipework in the primary circuit must be 28mm diameter
and the flow pipe must rise continuously from the boiler to
the open vent.
If an indirect cylinder is used then the primary circuit should
be filled with a suitable inhibitor to prevent the build up of
scale and corrosion.
HOT WATER SYSTEM
®
INSTALLATION INSTRUCTIONS
A
B
405 mm
400 mm
Minimum
This Dimension Is The
Minimum Level Area
Required To Enable The
For Overall Sizes Of
Hearth See The
Section Titled "Hearth".
Doors To Be Opened.
Fig. 4. Limiting Dimensions Of Hearth
660 mm
The shaded area on the face of
the surround is the minimum flat
area required.
750 mm
Fig. 5. Limiting Dimensions Of Surround And Opening
Drain Cock at Lowest Point
Drain Cock
Indirect Hot Water Cylinder
Cold Water Tank
Overflow
Feed and Expansion Tank 22mm Open Vents
Overflow
Domestic Hot Water Draw Off
Gravity Return 28mm
Gravity Flow 28mm
Fig. 6. Typical Gravity Hot Water System
charnwood
Dimension A:
Max. 470mm (18 ”)
Min. 405mm (16")
Dimension B:
Max. 575mm (23")
Min. 555mm (21 ”)
½
¾
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Charnwood LA20i wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info