TDMA CONTROL 601/701:
10
Published 07/2007
Hot Water Back up Heating Extra Com-
fort Temp 40...80°C
If the circulation and bath button is pressed three times
within 5 seconds the hot water back up heating target
temperature is raised to the set value for a time, thereby
acheiving a higher, comfortable, hot water temperature.
Using this function for providing hotter water only when
required allows significantly higher energy savings. This
function also operates during otherwise time switch con-
trolled back up heating shut down periods.
Hot Water Back up Heating:
Time Switch: On / Off
When the time switch is set to „On“, hot water back up
heating only occurs during the two selected time windows
/ operating periods.
Hot Water Back up Heating:
Each Day/Daily/Wkends-Wkdays
The time switch can be pre-set to accomodate individual
customer requirements. Two operating periods can be set.
Each Day: Different operating periods on different days.
The operating periods for each day are entered sepa-
rately.
Daily: The same operating periods are required each day.
The operating periods need only to be set once.
Weekends/Weekdays: The operating periods need only
be entered once for weekdays and once for weekend (Sat-
urday and Sunday) operating.
Example: Hot Water Back up Heating
Time Switch:
On
Time Switch Time:
Weekends/Weekdays
Weekday On:
08:00 (am)
Weekday Off:
16:00 (pm)
Weekend On:
09:00 (am)
Weekend Off:
17:00 (pm)
Back up heating for hot water will be activated as neces-
sary on weekdays between 08.00 and 16.00 and at
weekends between 09.00 and 17.00.
ADVICE:
In Variations 2 and 3 using CONTROL 601 and Varia-
tion 3 using CONTROL 701 hot water back up heating
can also be controlled via the boiler. The menu points
under „Water Input Data“ remain and the „Boiler
On/Off“ function is activated when hot water back up
heating is demanded.
Hot Water Back up Heating: Input - Function – Output
Input
Function
Upper thermal store sensor
(in delivery package)
Time controlled hot water
back up heating
Circulation – Bath button
One off raising of the tar-
get temperature for hot
water back up heating
Output: Hot water back up heating, Boiler On/Off
2.4.2 Time Controlled Hot Water Circulation
The time controlled hot water circulation enables large en-
ergy savings without any reduction in comfort. The circula-
tion pump can be activated via a button positioned in the
living space of the house and an integrated time switch. If
this button (circulation and bath button) is pressed once,
the circulation function is activated and the circulation
pump will run for the set time period.
See Advice on page 8.
Circulation running time: 1...20 M i n.
The running time of the circulation pump can be set here.
The running time should be such that the hot water tap
which is furthest from the thermal store will provide hot
water.
After the pump switches off there follows an interval of 15
minutes during which the pump will not operate, even if
the button is pressed again.
Circuulation Time Switch: On / Off
If the circulation time switch is set to „On“, the circulation
pump will be activated during the set operating time peri-
ods for the set running time (circulation running time / in-
terval). Three operating periods can be set.
Setting the time clock is carried out as described in para-
graph 2.4.1.
Example: Hot Water Circulation
Circulation running time:
2 minutes
Circulation Time Switch:
On
Time Switch Time:
Weekend/Weekday
Weekday On:
08:00
Weekday Off:
16:00
Weekend On:
09:00
Weekend Off:
17:00
The circulation pump can be activated on weekdays be-
tween 08.00 and 16.00 and at weekends between
09.00 and 17.00 with a pump operating period of 2
minutes and an interval between operation of 15 min-
utes. Outside these time periods the pump will only run
if activated by pressing the circulation – bath button.
2.5 Heating, Heating Circuit and Heating Support
Operating Functions (Heating Input Data)
2.5.1 Heating
Main Menu 12:34
Heating Input
The heating system settings are entered at the following
menu points.
Heat limit: Daytime external
temp: 0..40°C
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Consolar Control 601 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info