743662
59
Zoom out
Zoom in
Vorherige Seite
1/63
Nächste Seite
TDMA CONTROL 601/701:
59
Published 07/2007
5.7 Electrical Connection
The CONTROL 701 must be connected to an external
mains electricity supply at 230 V ± 10 % (50-60 Hz). The
connection is made at the L/ N/ PE clamps (see connec-
tion circuit board diagram 2).
Outputs 1 – 14 are each 230 Volt outputs. Their users are
connected to clamps A1 to A14.
Outputs 15 and 16 are voltage free outputs. Output 15
should be connected to clamps U1A/ U1M/ U1B. U2A/
U2M / U2B are where the user of output 16 is connected.
When outputs 15 an 16 are not activated, contact M-A is
open and contact M-B is closed.
Should the voltage free output have a 230 V output, the
operating voltage for outputs A15 and A16 can be a-
chieved using a bridge from clamp LS to U1M or U2M.
If a modulated input signal boiler is connected, it should
be connected to clamps U (0 – 10V) and GND.
The temperature sensors are connected to clamps F1 to
F16. The polarity of the temperature sensor connections is
open to choice. To prevent damage to the collector sensor
from being struck by lightening, a high voltage protection
for the installation is recommended (Art.-N
o
. RE500).
Clamps D1 and D6 are where the digital inputs are to be
connected.
ADVICE ON ELECTRICAL INSTALLATION GUIDELINES:
The relevant electrical installation guidelines must be
followed. The temperature sensor cables carry a low
voltage and must not be laid in the same channels as
other cables carrying voltages higher than 50V.
NOTE ON CONNECTION LAYING:
The connections should be made following the Regula-
tor Connection Information given in paragraph 4.
ADVICE ON SENSOR FAULTS:
If there is a faulty sensor and the flashing display pre-
vents setting the regulator, the sensor fault notification
can be overridden for 5 minutes by pressing "+" and "-
".
ADVICE ON POSITIONING THE COLLECTOR SENSOR:
The collector sensor should be fitted to the furthest pos-
sible absorber plate, so that it is also exposed to the in-
solation. Incorrect positioning of the collector sensor
can lead to inexact temperature measuring in the col-
lector and to a malfunction of the regulator.
If an immersion casing is used a good contact between
the sensor and the casing must be ensured. In must
cases using heat conducting paste is recommended. On
no account should the collector sensor be fitted outside
the collector.
Example of maximum cable lengths:
Sensor/Interface
Cable
Length up to
PT 1000
2 X 0.75 mm
25 m
PC-Interface
With standard
serial cable
50 m
Fuses
L1 Phase (black)
PE earth wire (yellow-green)
Solar pump
N Nullleiter (blue)
Output 1…14 (230V)
Digital inputs
3 and 4
Temperature sensor F1…F8
Module 1
Insolation sensor
Remote
Control
Module.
Output
Output 16
2,5AT
Output 1-4/LS
Temperature sensor F9…F16
Digital /inputs
5 and 6
Module 2
Output 15
2,5AT
Output 5-9/LS
2,5AT Output 10-
1-4/LS
Digital inputs
1 and 2
Diagram 2: Connection circuit board of the CONTROL 701 with solar pump connection example
CONTROL 701
59

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Consolar Control 601 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info