5.5 Setting the System Variables
To prevent faulty circuits occuring when commissioning the
system, all connections should be made in the following
order:
1. Plug in the sensor and mains connections
2. Set the required system variations (see Functions
Overview on page 5)
3. Disconnect the mains voltage and connect the
outputs
Not following this order can lead to faulty circuits develop-
ing on commissioning the system because the „Factory set-
tings“ Variation 1 which are set when the system is deliv-
ered may not correspond with the required output circuit.
5.6 Installing
All installation work should be carried out indoors. Shut off
the mains electricity supply. After undoing the screws (1)
the housing upper casing (2) can be lifted off towards the
front (see Figure 1). When closing the casing it is impor-
tant to make sure that the delicate circuit board on the lid
fits into the grooves (4) on the lower casing. Using a drill
to make the holes, attach back plate (3) of the housing cas-
ing to an inside wall. Now the electrical connections can
be made.
ATTENTION:
Never remove the casing lid if the mains electricity
supply is connected!
Diagram 1:CONTROL 701 Casing