555814
7
Zoom out
Zoom in
Vorherige Seite
1/92
Nächste Seite
7
GB
Always stop the engine before re lling the fuel tank
and clean the machine after lling the fuel tank.
Do not inhale fumes from petrol.
Electricity
Do not touch the generator if you have wet hands
Do not operate the generator in wet conditions.
Do not operate the generator near water.
Never connect two generators together.
Never connect the generator to any commercial
power outlet.
Make sure any extension cords used are in a safe
condition and of suf cient capacity for the task.
Ensure that the load on the generator falls within its
capacity as speci ed in the table before plugging in
any cords.
To prevent an electric shock, make sure to ground
the generator. Connect a piece of cable between
the ground terminal on the generator and an exter-
nal ground point.
Fire and burn hazards
The exhaust system gets hot enough to ignite some
materials:
- keep the generator at least 1 meter away from
buildings and other equipment during operation.
- keep ammable materials away from the genera-
tor.
The exhaust becomes very hot during operations
and remains hot for a while after stopping the en-
gine:
- Let the engine cool before storing the generator
indoors.
- Do not touch the hot exhaust with your hands.
Gasoline is extremely ammable and is explosive
under certain conditions. Do not smoke or allow
ames or sparks where the generator is refueled or
where gasoline is stored.
Fuel vapors are extremely ammable and may ig-
nite after the engine has started. Make sure that any
spilled fuel has been wiped up before starting the
generator.
3. USE
BEFORE STARTING THE GENERATOR
Fill and check oil level (quantity is 0,6 L)
Always check the oil level (with machine in a level
position) before starting and if the engine unexpect-
edly stops ( g. 2).
The generator has a low oil sensor and may cut
out or fail to start if the oil level is too low. Stop the
engine immediately when the oil warning light (3) is
on.
For general use you can use an «al temperature» oil
10W-40
0 ºC SAE#10
0 ºC - 25 ºC SAE#20
25 ºC - 35 ºC SAE#30
35 ºC SAE#40
Fill and check fuel level
Use unleaded fuel only (octane level 92 and more)
Remove any power cords
Turn power switches off
Do not over ll – leave air gap at top of fuel level
Always screw down fuel cap
Clean up any spilled fuel
Do not smoke while operating the generator
Always use caution!
Starting the generator
1
1. Turn on fuel tap (17).
2. Turn on engine switch (4).
3. Move choke lever (15) to closed position (to restart
a warm engine, leave the choke lever in open or
half-open position).
4. Pull slowly on the starter cord until it engages, then
pull sharply to start the engine (16).
5. Allow the engine to run until it warms up, and then
move the choke lever to the open position (15).
6. Plug in the power cord and switch the AC-switch
to «ON» (6).
Stopping the generator
1
1. Turn AC-switch to «OFF» (6)
2. Unplug all cords (11)
3. Turn engine switch to «OFF» (4)
4. Turn off fuel tap (17)
The generator is equipped with DC output (12 V / 8,3 A)
that allows to charge batteries through the cable sup-
plied. Observe polarity (red lead to +, black lead to -).
4. SERVICE & MAINTENANCE
PERIODIC MAINTENANCE
Daily (pre-operation check)
Check engine oil level
Check choke operation
Check recoil starter operation
1
st
Month or 20 hrs
Replace engine oil
3 Months or 50 hrs
Check condition of spark plug. Adjust gap and
clean. Replace if necessary.
Clean, replace if necessary.
6 Months or 100 hrs
Replace engine oil
Clean fuel tap and fuel tank lter. Replace if neces-
sary.
• Check ttings and fasteners. Replace if necessary.
12 Months or 300 hrs
Contact a specialized service centre to check the
valve clearance.
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Defort DPG-2500 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info