4.1.2- Positioning and anchoring
To ensure the proper functioning of the heat pump water heater
and to facilitate maintenance work, a space must be left free
around the appliance, as well as a minimum ceiling height so
that the hood can be removed.
• It is PROHIBITED to install the appliance:
- Outside.
- In rooms exposed to frost, where the temperature is less than
7°C, including when the appliance is operating.
- In humid rooms which have signicant steam or vapour
emissions (for example, a bathroom).
- In rooms where there is any risk of explosion due to gas,
pollution or dust.
Avoid placing the appliance close to bedrooms to minimise
noise pollution.
Do not install the air intake nozzle near a vapour exhaust
(minimum distance of 0,6m).
3.2 - Technical specications and
performances
4.1- Placement and positioning
• It is PROHIBITED :
- To let the appliance operate using air intake which contains
solvents or explosive materials.
- To use air intake which contains grease, dust or aerosol particles.
- To connect vented exhaust hoods to the ventilation system.
-To use air intake containing combustion materials from a boiler.
4 - INSTALLATION
INSTALLATION PRECAUTIONS :
The appliance must not be installed near a
perpetual ame or other source of ignition.
The appliance must be installed in such a way so
as to avoid mechanical damage to the appliance.
4.1.1- Placement choice
Heat pump performance
Nominal volume L 200 270
Max. input power W 1900 1900
Air temperature range OC 7 to +35 7 to +35
DHW* temperature with heat
pump
OC 30 to 60 30 to 60
Max. heat pump power
consumption W 700 700
Air ow rate m3/h 320 to 400 320 to 400
Sound pressure level at 1m** dB(A) 37/40 37/40
Refrigerant -/kg R290 /0.15 R290 /0.15
Global warming potential kg 0.45kg CO2
equivalent
0.45kg CO2
equivalent
Type of air connection Exterior or
ambient air Exterior or
ambient air
Normative Data (EN 16147)
Draw cycle L L
COP*outdoor air +7
oC) 3.19 3.14
Reserve capacity W 23 25
Hot water reference
temperature
O
C 54.2 55.8
Heating time 7H04 10H15
Energy class - A+ A+
Seasonal energy eciency % 132 130
Vmax L 247.4 349.3
V40 td L 614 650.4
COP* (ambient air +15oC) 3.37 3.47
Dimensions and connections
Dimensions mm Ø630 x H 1460 Ø630 x H 1780
Weight when empty kg 56.5 63
Air connection diameter
(intake / exhaust)
mm 160 160
Max. length for air ducts m Flexible tube: 6m
Rigid pipe: 12m
(intake + exhaust)
Connection diameter for
DCW* and DHW* inches M 3/4" M 3/4"
Electrical power supply V-Hz-A 230V50Hz-8A 230V50Hz-8A
Protection rating - IPX4 IPX4
D-curve circuit breaker A 8 8
Tank
Materials / protection Stainless
steel
Stainless
steel
Maximum service pressure MPa0.6 6 bars) 0.6 6 bars)
Max. condensates ow rate L/h 0.3 0.3
Built-in electrical back-up
power (85-C safety setting) W 1200 1200
Max. temp with electrical
back-up CO65 65
- INSTALLER HEAT PUMP WATER HEATER 200 -270L AIR D/2 - MANUAL-
6
EDEL AIR
200L D/2 EDEL AIR
270L D/2
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Dimplex Edel 200 AIR D-2 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Dimplex Edel 200 AIR D-2

Dimplex Edel 200 AIR D-2 Bedienungsanleitung - Holländisch - 48 seiten

Dimplex Edel 200 AIR D-2 Installationsanweisung - Holländisch - 48 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info