The oor must be able to support the weight of the heat pump
water heater (weight of the heat pump water heater lled with
water 200 L/ 270 L= 260 kg / 335 kg).
If installed without piping, the appliance must be installed in non-
heated premises (of at least 20m2 and away from neighboring heated
rooms.
•If the space available under the ceiling is less than 60cm in height
above the water heater, it is recommended to install an elbow at the
air outlet and direct it towards the back or the sides.
•The heat pump water heater enables heat to be recovered from
the oor of non-heated, partially underground premises such as a
workshop or garage.
The heat pump water heater allows the dehumidifying and cooling
of rooms such as utility rooms or cellars.
4.2- Air connection
4.2.1 - Without piping
Partial piping
Exterior air Heated room
The heat pump can operate over a large air temperature range (from
-7°C to +35°C). The appliance extracts calories from exterior air. Partial
piping (using only 1 pipe) onto exterior air should be avoided as in
the winter it can cause the room to become signicantly colder.
4.2.2 - With piping
piping at the back piping on the right piping on the left
The heat pump water heater must be connected using
insulated air ducts with an interior diameter of 160mm.
90° Ø160 mm PVC elbows allow you to rotate the position of the
pipes connected to the appliance through 360o.
Total maximum length Ø160 :
• 6 m of exible hose
• 12 m of semi rigid piping
1 elbow= 1m
Rep. Description
Semi-rigid pipe Ø160mm - lg 2m
Insulated 90° elbow Ø160mm
Collars for attaching to wall (set of 2)
Connectors for insulated pipes (set
of 2)
Horizontal terminal for insulated pipe
Piping accessories are available to order and are designed for a
simple and ecient heat pump water heater connection.
The pipes (Ref. 730011) and the foam elbows (Ref. 730012), are
semi-rigid, light and thermally insulated.
They are assembled using an assembly connector. (Ref.730014).
If over 1m long, the pipes must be anchored to the wall using a collar.
(Ref. 730013).
The stainless steel horizontal terminal (Ref. 730015), is equipped
with a protective grill.
4.2.3- Piping accessories
4.3 - Hydraulic connections
• A new pressure-relief valve (not included) must be installed and
set to 6 bars on the domestic cold water supply of the appliance.
We would recommend a membrane valve.
The membrane valve system must conform to national and
domestic standards and regulations in eect.
The pressure-relief valve should be installed as close as possible
to the appliances cold water inlet and the water ow should
never be hampered by any accessory (valve, pressure-
reducer, etc...)
The pressure-relief valve drainage outlet must be installed in a
frost-free place, in a downward-sloping position.
The pressure-relief valve drainage outlet should be sized
according to building regulations and must never be obstructed.
It should be connected to a vertical draining pipe, using a funnel
which allows an open space of at least 20mm and which is at
least equal in diameter to the appliances piping connection.
• If the pressure of the domestic cold water supply is higher than 5
bars, a pressure-reducer should be installed above the pressure-
relief valve near the starting point of the installation (a pressure
of 4-5 bars is recommended).
• It is advised to t a shut-o valve above the pressure-relief valve.
• For installations equipped with:
- piping of a small diameter
- ceramic plate valves
A domestic water expansion vessel, or anti-hammer valves
which are adapted to the installation should be installed as close
as possible to the shut-o valve.
The following materials should be used for the
The vertical position of the heat pump
water heater must be strictly respected.
If not, there is a risk of condensates
leaking and resulting in a water leak at
the base of the appliance.
• Use the anchoring point at the bottom of the tank to x the
appliance to the oor, using the metal tab (pre-assembled under
the foot) and an ØM8 screw which can be then dowelled into
the ground (see Rep.).
- INSTALLER HEAT PUMP WATER HEATER 200 -270L AIR D/2 - MANUAL - 7
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Dimplex Edel 200 AIR D-2 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Dimplex Edel 200 AIR D-2

Dimplex Edel 200 AIR D-2 Bedienungsanleitung - Holländisch - 48 seiten

Dimplex Edel 200 AIR D-2 Installationsanweisung - Holländisch - 48 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info