5.9 - Installer menu
It may be necessary to adjust certain temperature settings to
optimise the performance of the heat pump water heater,
depending on how the appliance is installed.
Accessing the installer menu:
• Press
Turn the dial until the screen displays
«installer menu.»
• Press the «Clock settings» and
«Menu» buttons simultaneously
Keep both buttons pressed down for 3 sec. until the
screen displays «pv mode»
To adjust the installation settings
settings
To activate photovoltaic operation
MODE PV
To go back to default settings
reset par.
To display temperatures of sensors
and inlets
display
To set the meters running, count
start-ups, etc.
counters
5.9.1 - PV mode
1. If the PV mode regulator is connected to connectors
1 and 2 on the electronics board, PV mode must be
activated.
The electrical energy which is produced is stored in
the form of hot water. The PV function can be set to
two dierent levels of production.
PV ECO = the lower level of the photovoltaic energy
production. The heat pump generates a higher
water temperature. The hot water temperature
must be somewhere between the regular hot water
temperature and 60°C (factory setting = 60°C).
PV MAX = the higher level of photovoltaic electricity
production. The heat pump and electrical back-up generate a
higher water temperature. The hot water temperature must be
somewhere between the eco mode hot water temperature and
65°C (factory setting = 65°C).
2. Turn the dial to set the mode:
- Menu INST. MENU PV mode.
3. Select « Yes »
4. Press the dial to conrm.
5. Press Menu.
6. Set the domestic hot water temperature.
7. Turn the dial to select the primary function:
- Menu INST. MENU MODE PV PRIORITY
• Yes: the signals from connectors 1 and 2 take precedence over
eco and frost protection modes.
• No: The eco and frost protection modes take precedence over
the signals from connectors 1 and 2.
N.B.: If PV mode is chosen as the primary function, the domestic
hot water will also be heated during non-selected time periods, e.g.
in holiday mode and outside of the programmed time slots.
If you only wish the domestic hot water to be heated during
authorised time slots, adjust the settings to No.
8. Press the dial to conrm your choice.
• For products which are equipped with an extra thermal heat
exchanger, no boiler request is sent when the heat pump is switched
on. Only the electrical back-up is on, to use the energy produced by
the PV function.
•When fan mode is activated, option 3 may no longer be chosen.
•The load shedding function is not available.
5.9.2 - Adjusting the operating settings
Select setting Modify the
setting
+
settings
Enter
• Press to return to the main menu.
5.9.2.1 - ANTI-BACT -anti-legionellosis cycle
Example :
anti-bact = 8,
temp. water = 60 C
the anti-legionellosis cycle
will run every 8 days at 10pm
Select number of days
ANTI-BACT
no
ANTI-BACT
8 d
Factory setting anti bact = NO
Factory setting temp. water = 60 C
TEMP. water
60 C
Select the temperature
Conrm
Conrm
• If the set temperature for domestic hot water is already 60°C
(see § «Setting the desired water temperature»), there will be no
anti-legionellosis cycle as it is already running continuously.
• Press to return to the main menu.
Parameter Description Unit Time
range Factory
setting
mode pv Activation of
photovoltaic mode yes
no
no
priority Interval of anti-
legionellosis cycles yes
no
yes
Parameter Description Unit Time
range Factory
setting
anti-
bact
Time interval
for anti-
legionellosis
cycle
days 0-99 0
fan
mode
Ventilation
mode 1,2,3 1
toC mini Min. temp for
electrical back-
up
0 or 1 0
shedding Load shedding
level 0,1,2 1
max.
time
Max. heating
time hours No,
auto, 1
to 24
No
- INSTALLER HEAT PUMP WATER HEATER 200 -270L AIR D/2 - MANUAL - 13
13

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Dimplex Edel 200 AIR D-2 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Dimplex Edel 200 AIR D-2

Dimplex Edel 200 AIR D-2 Bedienungsanleitung - Holländisch - 48 seiten

Dimplex Edel 200 AIR D-2 Installationsanweisung - Holländisch - 48 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info