New Wall Construction
1. Select a suitable location that is not susceptible to
moisture and is away from drapes, furniture and high
trafc.
2. Place the replace in the desired location to see how
it will look in the room.
3. Mark the desired location on the oor.
4. Use studs to frame an opening of 680 mm wide X 585
mm high X 229 mm deep.(DF2608) Use studs to frame an
opening of 775 mm wide X 654mm high X 298 mm deep.
(DF3020)
Option #1
The power cord can be run from behind the trim and
along the wall to an outlet near the replace.
Option #2
A new outlet can be installed inside the framing
construction. Plug the replace into a 10-13Amp/230-
240 Volt outlet. If the cord does not reach you may use
a 3-core type extension cord rated for a minimum of
10 Amps.
Existing Fireplace
1. Seal all drafts and vents with a non-brous insulation
material to prevent any chimney debris from falling onto
the replace. Do not install into an existing replace that
is prone to dampness.
2. Cap the top of the chimney ue to prevent rain from
entering.
3. Plan your electric power supply.
4. The power cord can run along the front of the hearth
to an outlet near the replace.
Thermal Safety Cut-out
The built-in overheat cut-out, switches off the appliance
automatically in the event of a fault! Should this occur
switch off the appliance or disconnect the mains plug
from the socket.
Remove any obstructions which may have caused the
overheating. After a short cooling down phase, the
appliance is ready for use again! If the fault should occur
again, contact your local dealer!
WARNING: In order to avoid a hazard due to inadvertent
resetting of the thermal cut-out, this appliance must not be
supplied through an external switching device, such as a
timer, or connected to a circuit that is regularly switched
on and off by the utility.
Maintenance
WARNING: ALWAYS DISCONNECT FROM THE POWER
SUPPLY BEFORE ATTEMPTING ANY MAINTENANCE.
Light Emitting Diode
This re is tted with LED (Light Emitting Diode) lamps. These
LED lamps are maintenance-free and should not require
replacing during the life of the product.
Remote Control - See Fig. 3
The maximum range of use is ~ 5metres.
NOTE: It takes time for the receiver to respond to the
transmitter.
NOTE: The receiver for the remote control is located in
the display, aim the remote control in this direction when
inputting commands.
Do not press the buttons more than once within two
seconds for correct operation.
Battery Information - See Fig. 3
1. To activate the remote control remove the clear battery
isolation strip at the base of the remote control, which
is used to ensure your remote control reaches you fully
charged.
2. To replace the remote control battery, turn over the
remote control, and follow the diagram embossed on the
remote control
3. Only use CR2025 or CR2032 size of batteries.
Installing Front Glass- See Fig. 5, 6 & 7
NOTE: The outer glass is shipped separate to the rebox.
1. Remove the three screws holding the side trim as shown
in Fig. 5. and remove the metal trim.
2. Unpack the glass, ensure it is free from dust and nger
marks and slide in to position as shown in Fig. 6.
3. Position the metal trim removed in step 1, and secure
with the three screws as per Fig. 7
Fitting- See Fig. 4
IMPORTANT: If not using a Dimplex mantel, the replace
must be installed in an enclosure with the following
MINIMUM dimensions(Figure 4).
1. Select a suitable location that is not susceptible to
moisture and is at least 1 meter away from drapes,
furniture and high trafc.
2. Store the replace in a safe, dry and dust free location.
3. Clearance for air circulation beneath the replace
is provided by two spacers. DO NOT INSTALL FIREPLACE
DIRECTLY ON CARPET OR SIMILAR SURFACES WHICH MAY
RESTRICT AIR CIRCULATION. If installing the replace in
a carpeted area, place a one-piece, solid at surface
under the replace. Ensure that all feet rest securely on
this surface!
4. In some jurisdictions this appliance is supplied without
a plug this is to comply with the local regulations. In such
instances this appliance must be installed by a suitably
qualified installer and the means for disconnection must
be incorporated in the fixed wiring in accordance with
the local wiring rules.
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Dimplex Firebox DF 2608 Opti-flame wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info