English LA 60TU
11 Device information
1 Type and order code LA 60TU
2Design
2.1 Model / controller Universal / external
2.2 Thermal energy metering Integrated
2.3 Installation location / degree of protection according to EN 60529 Outdoor / IP24
2.4 Antifreeze condensate tray / heating water Heated / yes1
1. The heat circulating pump and the heat pump manager must always be ready for operation.
2.5 Performance levels 2
3 Operating limits
3.1 Heating water flow / return2°C
2. At air inlet temperatures of -20 °C to 0 °C flow temperature rising from 55 °C to 65 °C (see operating limits diagram).
up to 65 ± 2 / from 18
Air (heat source) °C -20 to +35
4 Performance data / flow rate
4.1 Heating water flow rate /
internal pressure differential A7/W35/30 m³/h / Pa 10.4 / 8300
A7/W45/38 m³/h / Pa 7.7 / 4500
Minimum heating water flow A7/W55/45 m³/h / Pa 5.3 / 2100
4.2 Heat output / COP 3
3. These data indicate the size and capacity of the system according to EN 255 (10K at A2) and EN 14511 (5K at A7) without weather-proof protective cover. For an analysis of the
economic and energy efficiency of the system, other parameters, in particular the defrosting capacity, the bivalence point and the regulation, should also be taken into consideration.
The specified values have the following meaning, e.g. A7 / W35: External air temperature 7 °C and heating water flow temperature 35 °C.
EN 255 EN 14511
at A-7 / W35 kW / --- 4
4. 2-compressor operating mode
39.3 / 3.0 39.2 / 2.9
kW / --- 5
5. 1-compressor operating mode
21.3 / 3.1 21.2 / 3.0
at A2 / W35 kW / --- 450.0 / 3.7 50.0 / 3.6
kW / --- 526.4 / 3.8 26.4 / 3.7
at A7 / W35 kW / --- 460.1 / 4.1
kW / --- 531.9 / 4.3
at A7 / W55 kW / --- 455.0 / 2.8
kW / --- 528.3 / 2.9
at A10 / W35 kW / --- 466.6 / 4.4 64.6 / 4.2
kW / --- 538.4 / 4.6 33.6 / 4.4
4.3 Sound power level Normal operation / reduced operation dB(A) up to 74 / up to 70
4.4 Sound pressure level at a distance of 10 m (air outlet side) 6
Normal operation / reduced operation dB(A)
6. The specified sound pressure level corresponds to the operating noise of the heat pump in heating operation with a flow temperature of 35 °C.
The specified sound pressure level represents the free sound area level. The measured value can deviate by up to 16 dB(A), depending on the installation location.
up to 50 / up to 46
4.5 Air flow m³/h 14000
5 Dimensions, connections and weight
5.1 Device dimensions without connections7H x W x L mm
7. Note that additional space is required for pipe connections, operation and maintenance.
2300 x 1900 x 1000
5.2 Device connections for heating system Inches R 2“
5.3 Weight of the transportable unit(s) incl. packaging kg 915
5.4 Refrigerant / total filling weight type / kg R417A / 20,9
5.5 GWP value / CO2 equivalent --- / t 2346 / 49
5.6 Refrigeration circuit hermetically sealed yes
5.7 Lubricant / total filling quantity type / litres Polyolester (POE) / 8.28
6 Electrical connection
6.1 Load voltage / Fuse protection 3~/N/PE 400 V (50 Hz); Z50 A
6.2 Control voltage / Fuse protection ---
6.3 Starting current with soft starter A 78
6.4 Nominal power consumption A2 W35/
max. consumption 3, 4kW 14.9 / 27.6
6.5 Nominal current A2 W35 / cosϕ4 A / --- 29.5 / 0.8
6.6 Max. power consumption of compressor protection
(per compressor) W 70, thermostatically controlled
7 Complies with the European safety regulations 8
8. See CE declaration of conformity
8 Additional model features
Type of defrosting (according to need) Reverse circulation
24

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Dimplex LA 60TU wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Dimplex LA 60TU

Dimplex LA 60TU Bedienungsanleitung und Installationsanweisung - Holländisch - 28 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info