EN-12 452162.66.04 · FD 9912 www.gdts.one
English LAW 9IMR - LAW 14ITR
Step 2: Fastening
Align the centre of the pipe and tighten the screw nuts by
hand.
Tighten the screw nuts with a spanner until they click.
Torques.
Step 3: Preventing foreign bodies from entering the
unit
Seal all pipe openings well with putty or a different type of
insulation (available separately).
If insects or small animals enter the outdoor unit, they can
cause short circuits in the control cabinet.
Lay the pipes. To do this, cover the coupling device of the
indoor unit with insulation and fix in place with two adhe-
sive tapes.
Adequate heat insulation is extremely important.
ATTENTION!
!
!
Never open the valves of the outdoor component.
Carry out the work from Cap. 8.2 on pag. 12
and Cap. 8.3 on pag. 13 first of all.
8.2 Electrical connections
8.2.1 Outdoor unit
NOTE
º
The DIP switches on the circuit boards in the outdoor unit
have no function. The positions of the DIP switches must
remain in their factory default and must not be changed!
Two cables must be connected on the outdoor unit:
A 'mains cable' and a 'data cable'
Both cables must be laid between the indoor and outdoor unit.
The mains cable is used to supply the outdoor unit with power
and the data cable is for communication between the outdoor
and indoor component. The VDE directives and regulations and
local conditions must be taken into account in the design and
installation of the two cables.
The indoor component already contains a safeguard element
for the outdoor component. The safeguarding of the entire heat
pump must also take place externally.
The mains cable on the 9 kW outdoor unit must be three-core
and be connected to the terminals L / N / PE (power supply).
With the 14 kW outdoor unit, the mains cable must be 5-core
and connected to the terminals R / S / T / N / PE (see Appendix,
Load connection diagram Chap.2.3).
If no connection lugs are available, proceed as follows.
No cables with different thicknesses may be connected to
the connecting terminal. (one of the cables may come
loose during strong heat development.)
Multiple cables of the same thickness must be connected
as shown in the figure.
A shielded 2-core cable must be used as a data cable.
The data cable is connected to the terminals (Bus_A(+) /
Bus_B(-)) of the gateway circuit board (small circuit board in the
outdoor component) and to the heat pump manager (+/-) in the
indoor component (see Appendix, Connection diagram Chap.
2.5).
Outdoor unit
Continuously
Continuously
Pipework of
the air side
Pipework of
the liquid side
Putty or insulation (available separately)
Drain hose
(if required)
Connection cable
Connection pipe
Round connection lugs Mains cable
38

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Dimplex LAW 9IMR wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info