Operating the Fire
This section describes how to activate your re using either the manual controls or remote control.
MANUAL CONTROLS
The manual controls are located beneath the hinged ap. (Fig.10 for Manual Control lay out)
Switch ‘A’:- Controls the electricity supply to the Fire.
Note: This switch must be in the ‘ON’ ( I ) position for the Fire to operate either with or without heat.
Switch ‘B’:- Press
once to turn on the ame effect. This will be indicated by an audible beep. Although the main lights
operate immediately it will take a further 30 seconds before the ame effect starts.
Press
again to give ame effect and half heat. This will be indicated by two beeps.
Press
again to give ame effect and full heat. This will be indicated by three beeps.
Press
again to return to ame effect only. This will be indicated by one beep.
Press to put re in to standby mode. This will be indicated by one beep.
Control Knob ‘C’:- Controls the Thermostat setting.
Turning the control knob to the left will decrease the temperature setting, turning the control knob
to the right will increase the temperature setting.
Control Knob ‘D’:- Controls the intensity of the ame effect.
Turning the control knob to the left increases the ame effect, turning the control knob to the right will
decrease the ame effect.
SETTING THE THERMOSTAT
Ensure the re is plugged in and switch it on to the full heat setting. Turn the Control Knob ‘C’ fully to the right (max
temperature setting) to warm the room rapidly. When the room temperature has reached the desired level, turn
the thermostat knob back slowly until you hear the thermostat just click off. The heater will then maintain the room
temperature at the chosen level.
Note: Should your heater fail to come on when the thermostat is at a low setting, this may be due to the room temperature
being higher then the thermostat setting
THERMAL SAFETY CUT-OUT
A thermal safety cut-out is incorporated in the fan heater to prevent damage due to overheating. This can happen if
the heat outlet was restricted in any way. If the cut-out operates, unplug the heater from the socket outlet and allow
approximately 10 minutes before reconnecting. Before switching the heater back on remove any obstruction that may
be restricting the heat outlet, then continue normal operation.
Caution: In order to avoid a hazard due to inadvertent resetting of the thermal cutout, this appliance must not be
supplied through an external switching device, such as a timer, or connected to a switch that is regularly switched on
and off by the utility.
GETTING THE DESIRED FLAME EFFECT
1. The ame control knob ‘D’ (Fig.10) may be turned up or down to give a more realistic effect.
2. Generally the ames appear more realistic when the ame control is turned down.
2. Lift out the Sump Nozzle (Fig 3)
3. Insert lamps into lamp holders (Fig 4), carefully locating the pins into the holes (Fig 4a)
4. Push lamps rmly into place
5. Place the Transducer Unit into the sump and join the cable to the connector on the sump (Fig 5)
6. To ensure that the Transducer Unit is correctly placed in the sump, the tab on the Transducer Unit should be lined
up with the moulded recess in the sump (Fig 5a).
7. Ensure that the cable is not placed above the disc on the Transducer Unit (Fig 5b). To prevent the cable becoming
pinched between the nozzle and the sump, place the cable in the slot in the wall of the sump.
8. Replace the Sump Nozzle and secure it by turning the two red tabs by 90 degrees (Fig 6)
Filling the Water Tank
9. Place Water Tank in sink and remove cap (turn anti-clockwise to open) (Fig 7)
10. Fill Water Tank with decalcied tap water only. This is necessary to prolong the life of the ame and smoke
producing unit. The water should be ltered through a conventional domestic water lter unit and the lter should
be replaced regularly.
11. Screw the cap back on – do not overtighten.
12. Place the Water Tank in the Sump, with the tank cap facing down and the at side of the tank facing outward (Fig 8)
Assembling the re
13. Place the Fuelbed on top of the Water Tank and Mist Nozzle (Fig 9)
22

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Dimplex Moorefield wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Dimplex Moorefield

Dimplex Moorefield Zusatzinformation - Englisch - 4 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info