INSTRUCTIONS FOR INSTALLATION
18
Foreword
Dear Customer,
We would like to thank you for buying this DRU product.
Our products have been designed and produced to meet
the highest possible quality,performance and safety
requirements,allowing you to enjoy years of problem-free
use.
In this booklet you will find instructions for the installation
and use of your new appliance.Please read these
instructions and the manual carefully to familiarize yourself
with the appliance.If you require any further support,
please do not hesitate to contact your supplier.
Unpacking
Once the heater has been unpacked,all packaging should
be disposed of in the regular manner.
Connection
This appliance should be connected by a registered
installer.
INSTRUCTIONS FOR INSTALLATION
Gas type
This appliance can only be used and is only suitable for the
country and the type of gas mentioned on the type
identification tag.Check that the local gas type and
pressure correspond with the specifications on the gas
type plate.The type plate is on the inside of the casing.All
regulations applicable for gas installation,including any
locally enforced regulations,should be observed at all
times.The appliance must be connected by a qualified
installer.
For the appliance to work on propane or butane (G31 or
G30) it will have to be converted by a qualified installer.
A conversion set can be ordered through him.
Important
• Make sure that any curtains or other combustible
materials are at least 50 cm away from the heater.
• Beware! Touching hot parts of the heater can cause
burns and blisters!
• The appliance must be installed by a qualified fitter.
• DO NOT use a dust filter under or on top of the casing.
• DO NOT hang wet clothes or towels etc.on the heater
to dry!
• NB:To ensure the ignition works properly,the ignition
wire must come into as little contact as possible with the
metal parts of the heater and should therefore not be
wound round the gas or pilot-light pipes or the
thermocouple
Positioning the appliance
• The appliance should only be installed in a well ventilated
room,to ensure there will always be sufficient air supply.
• The appliance may not be installed against a wall of
combustible material unless the wall is protected with an
insulation panel.
• The connection between the pipe mouth and the flue
should be as short and straight as possible and the gas
control block easily accessible.
• The minimum distance between the back of the
appliance and the wall is 70 mm.
Connecting to the flue
• Have the chimney professionally cleaned before
connecting the appliance.Although the heater will still
work with only a very slight draught,we recommend that
the chimney be inspected for obstructions etc.annually.
• The internal diameter of the pipe mouth is 101 mm.
fig.3