3.3 Precautions / safety instructions during
installation
Carefully observe the following precautions/safety
regulations:
you should only install and maintain the appliance if you
are a competent installer in the fi eld of atmospheric gas-
red heating;
do not make any changes to the appliance;
use non combustible and heat-resistant materials for the
chimney breast, including the top of the chimney breast,
the material in the chimney breast and the back wall
against which the appliance will be placed;
take suffi cient measures to prevent temperatures of a wall
behind the chimney breast becoming too high, including
the materials and/or objects behind the wall;
comply with the minimum required internal measure-
ments of the chimney breast;
ventilate the chimney breast by means of the ventilation
holes, which will form a combined passage of at least
200 cm
2
;
only use the fl ue gas discharge / combustion air supply
system supplied by DRU;
do not place the appliance too tightly against the back
wall;
make sure the space between the adjustable feet is kept
free;
do not cover the appliance and/or do not wrap it in an
insulation blanket or any other material;
make sure that combustible objects and/or materials have
a distance from the appliance of at least 500 mm
only ever use the supplied wood / pebble set;
place the wood / pebble set exactly as described;
make sure the pilot burner and the space around it is kept
free;
make sure thermocouple 2 and the space around it are
kept free;
make sure there is no dirt in gas pipes and connections;
mount a gas tap directly next to the appliance;
check the connections for gastightness before using the
appliance;
use heat resistant electrical wiring;
place the electrical wiring in such a way that they are free
from the appliance;
replace torn or broken panes;
do not ignite the appliance until it is fully installed.
4. Instructions
Observe the following items during installation in order to
guarantee a proper and safe operation of the appliance:
mount the control box supplied as low as possible;
avoid that the ignition cable runs over the receiver;
avoid that the ignition cable touches or crosses the
antenna;
make sure the ignition cable cannot come into contact
with other wires;
avoid that the ignition cable runs alongside metal parts, in
order to prevent weakening of the spark;
properly fi nish the edges in case of a tight construction;
do not apply plaster on or over the fl anges;
avoid damages when removing/placing the pane;
clean the pane before you use the appliance, in order to
prevent dirt from burning in the glass;
make sure that the wires of thermocouple 2 cannot come
into contact with hot parts.
5. Removing the packaging
Note the following items when removing the packaging:
Check the appliance for damages during transport.
If necessary, contact DRU Service.
After removing the packaging, you should have the following
components:
- Socket spanner; you will fi nd it in the space between the
assembly frame and the combustion chamber;
- Decorative strips; you will fi nd them in the abovementi-
oned space as well;
After removing the pane, you can take the wood / pebble
set and the box with parts out of the combustion chamber.
!Caution Avoid damages when removing/placing the
pane.
Remove the pane as described in section 6.10.1.
Remove the wood / pebble set from the combustion
chamber.
Remove the box containing parts from the combustion
chamber.
In appendix 1/ table 5 you can see which parts you should
have after removing the packaging.
Contact DRU Service if you do not have all the parts after
you fi nished removing the packaging.
Dispose packaging in accordance with local regulations.
6. Installation
!Caution Install the appliance in the order described
in this chapter.
6.1 Regulations
Observe the applicable (installation) regulations.
Observe the regulations/instructions in this manual.
6.2 Type of gas
The data plate indicates for which type of gas, gas pressure
and for which country this appliance is intended. The data
plate is connected to a chain. It should remain connected to
the chain.
Check whether the appliance is suitable for
the type of gas and the gas pressure used at
the location.
Caution
31

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für DRU GLOBAL 100 BF wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von DRU GLOBAL 100 BF

DRU GLOBAL 100 BF Bedienungsanleitung - Deutsch - 20 seiten

DRU GLOBAL 100 BF Bedienungsanleitung - Englisch - 20 seiten

DRU GLOBAL 100 BF Bedienungsanleitung - Französisch - 20 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info