528138
34
Zoom out
Zoom in
Vorherige Seite
1/60
Nächste Seite
32
INSTALLATION MANUAL
!Caution Some heat-resistant insulation materials
contain volatile components that will
spread an unpleasant smell for a prolon-
ged time; these are not suitable.
Place the concentric system as follows:
Build the system up from (the connection stump of)
the appliance.
Connect the concentric pipe pieces and, if necessary,
the bends.
On each connection, apply a clip binding with silicon
sealing ring.
Use a self-tapping screw to fi x the clip binding to the pipe
on locations that cannot be reached after installation.
Apply suffi cient clamps, so that the weight of the pipes
does not rest on the appliance.
Determine the remaining length of the roof terminal.
Make sure the roof terminal has the right dimensions.
!Caution Make sure that the right insertion length
is maintained.
Connect the roof terminal to the concentric pipes.
!Caution - Make sure that the universal tile fi ts well
with the surrounding tiles;
- Make sure that the adhesive plate fi ts well
onto the fl at roof.
6.5.4 Connection of existing chimney
It is possible to connect the appliance to an existing
channel.
A fl exible SS pipe is placed in the chimney for discharging
ue gases. The surrounding space is used to supply
combustion air.
The following requirements apply when connecting to an
existing chimney:
- only allowed when used in combination with the special
DRU chimney kit. The installation manual is also supplied;
- the dimensions should be at least 150 x 150 mm;
- the vertical length has a maximum of 12 meters;
- the horizontal length has a maximum of 3 meters;
- the existing chimney has to be clean;
- the existing chimney has to be tight.
If the appliance is installed into an existing chimney by
means of a chimney kit, there may be a slight loss in heat
output.
For setting the appliance, the same conditions/instructions
apply as for the concentric system described above.
6.6 Placing the chimney breast
The appliance is designed to be mounted tightly in a new
chimney breast.
In order to provide proper heat discharge, there should be
suffi cient space around the appliance.
The chimney breast should be ventilated suffi ciently by
means of ventilation holes.
- Use non combustible and heat-resistant
materials for the chimney breast, inclu-
ding the top of the chimney breast, the
material in the chimney breast and the
back wall of the chimney breast;
- Make sure that the appliance is not car-
rying the weight of the chimney breast
when using stone-like materials;
- The ventilation holes – which should be
mounted as high as possible – should have
a combined passage of at least 200 cm
2
.
!Caution When placing the chimney breast, you
should take the following into account
(see fi g. 2a and fi g. 2b):
- the location of the control box (K): it
should be placed with a distance of
850 mm to the left or to the right of the
appliance – as low as possible;
- the measurements of the control box; see
Placing the Control Box section 6.7;
- the location of the ventilation holes (V);
- measurement of the pane, so it can be
placed/removed after placing the chimney
breast;
- the protection of the gas control and the
pipes against cement and plaster.
!Tip You should preferably apply the ventila-
tion holes on both sides of the chimney
breast. You can use DRU ventilation
elements.
Check whether the concentric system is placed correctly.
Check the fi xture of the clip binding with self-tapping
screws on places that cannot be reached later on.
Maintain suffi cient space around the appliance in the chim-
ney breast, so the heat can escape:
- minimum internal height: 1350 mm;
- minimum internal width: 1450 mm.
Do not apply plaster on or over the fl anges (see fi g. 2a
and fi g. 2b, maximum plaster line M), because:
- the heat of the appliance could cause cracks;
- it will no longer be possible to remove/place the pane.
When using stone-like materials and/or plaster fi nishing,
the chimney breast should dry for at least 6 weeks before
it is taken into operation, in order to prevent cracks.
6.7 Placing the control box
The control box (K) is placed as low as possible in the
chimney breast (see fi g. 2a and fi g. 2b). The control box is
not part of the appliance's standard equipment and is availa-
ble at your dealer.
!Caution The bottom of the control box may not
be placed higher in the appliance, than the
burner bed.
Caution
34

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für DRU GLOBAL 70 XT wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von DRU GLOBAL 70 XT

DRU GLOBAL 70 XT Bedienungsanleitung - Deutsch - 20 seiten

DRU GLOBAL 70 XT Bedienungsanleitung - Englisch - 20 seiten

DRU GLOBAL 70 XT Bedienungsanleitung - Holländisch - 20 seiten

DRU GLOBAL 70 XT Bedienungsanleitung - Französisch - 20 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info