528138
37
Zoom out
Zoom in
Vorherige Seite
1/60
Nächste Seite
English
35
INSTALLATION MANUAL
Global 70 / 70 XT
7.1.1 Placing / replacing the batteries
Follow the procedure below when placing the batteries:
Open the door of the control box.
• Pick up the receiver.
• Slide the cover off.
• Place or remove the 4 penlite (AA type) batteries.
!Caution - Avoid a short circuit between the
batteries and metal objects/parts;
- Observe the “+” and “-” poles of the
batteries and the holder;
- Use alkaline batteries.
Slide back the cover.
Place back the receiver.
!Caution Batteries are regarded as “small chemical
waste” and may therefore not be dis-
posed with the household rubbish.
8. Final check
In order to check whether the appliance is working pro-
perly and safely, you must perform the following checks
before the appliance is used.
8.1 All connections must be gastight.
All connections must be gastight.
!Caution The gas control can be subjected to a
maximum pressure of 50 mbar.
Check the connections for gastightness
8.2 Gas pressure / pre-pressure
The burner pressure is set at the factory; see data plate. It
is not necessary to check the burner pressure.
The pre-pressure in house installations
should be checked, as they can vary.
Check the pre-pressure; see fi g. 17 for the measuring nipple
on the gas control.
Contact the gas company if the pre-pressure is not correct.
8.3 Ignition pilot and main burner
For igniting the pilot and main burners, see the
User Manual, chapter 4, section 4.2, Remote Control.
- During the ignition process, you are not
allowed to operate control button B on
the gas control manually;
- Always wait 5 minutes after the pilot
burner has gone out, before you re-ignite
the appliance.
- Do not turn the pilot burner lower by
using the settings on the gas control.
8.3.1 Pilot burner
Check the ignition of the pilot burner:
- the pilot burner should start at the fi rst attempt.
If the pilot burner does not ignite:
check if the ignition sparks:
a) If not, the ignition cable is probably not lying free from
metal parts;
b) If it does, there is probably still air in the pipe.
Bleed the pipe and/or
Lay the ignition cable free from metal parts.
8.3.2 Main burner
The burner should ignite smoothly and
should not pop as a result of delayed
ignition.
Check the function of the main burner from the standby
(pilot burner) position:
- after opening the gas valve, the main burner should burn
within a few seconds.
!Tip When the gas valve is opened, the motor
will run; this is audible.
1) If the main burner does not burn:
Check if button A on the gas control is in the position ON;
Check if the space surrounding the pilot burner is free
from objects;
Check the placement of the wood set.
If necessary, correct the above mentioned faults.
Test the main burner 5x for a good operation.
2) If the main burner ignites, but goes out again after
approx. 22 seconds, please:
Check the wiring of thermocouple 2 for:
- Loose wiring;
- Wrongly connected wiring;
- Short-circuit;
- Broken wire.
Check if thermocouple 2 is dirty.
Check if thermocouple 2 is positioned correctly in the
ame; see fi g. 18.
Check if thermocouple 2 is defective; see chapter 11,
table 4 under J7.
Check if the receiver is defective; see chapter 11, table 4
under J8.
If necessary, correct the above mentioned faults.
Test the main burner 5x for a good operation.
8.4 Flame image
The fl ame image can only really be assessed when the ap-
pliance has been burning for several hours. Volatile compo-
nents from paint, materials, etc., which evaporate in the fi rst
hours, will affect the fl ame image.
Caution
Caution
Caution
Caution
37

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für DRU GLOBAL 70 XT wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von DRU GLOBAL 70 XT

DRU GLOBAL 70 XT Bedienungsanleitung - Deutsch - 20 seiten

DRU GLOBAL 70 XT Bedienungsanleitung - Englisch - 20 seiten

DRU GLOBAL 70 XT Bedienungsanleitung - Holländisch - 20 seiten

DRU GLOBAL 70 XT Bedienungsanleitung - Französisch - 20 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info