515345
10
Zoom out
Zoom in
Vorherige Seite
1/32
Nächste Seite
10
5. CONFIGURATION OF THE ALARM REGISTERS
5.1 Sensor-1 monitoring
5.1.1 Sensor-1 as alarm contact
EasyAlarm
®
auto-detects a Plug&Protect-sensor and starts its monitoring if the system is armed. You can define the
behaviour for sensor-1 as following:
Example: A normally closed contact shall trigger an un-delayed alarm with a hands-free-connection independent from
position of the selection switch.
1. Slide function switch to PROG
2. Enter sequence *. 9. 3. 1. 7 5 6 #. #.. .
Current register (bit 7 -> bit 0) will be announced followed by “to modify press *., to stop press #.
3. If you want to keep current value proceed with step 6. Otherwise start modifying register by pressing *..
4. Enter sequence 0. 0. 1. 0 0 0. 1. 1. .
R-Siren Entry-Delay Connect. mode Sensor on.. Type
0: off 0:off 0: Listening-in I / II / III 00: inactive
1: on 1:on 1: Hands-free 0 0 0 01: Normally open contact
0: enabled 10: Plug&Protect (auto-detected at power-on)
1: disabled input-2 is open => Normally open monitoring
input-2 is closed => Normally closed monitoring
5. Press key #. . 11: Normally closed contact
The new register (bit 7 -> bit 0) will be announced
6. Slide function switch to OFF
5.1.2 Sensor-1 for presence verification
You can also use sensor-1 to monitor missing activity (i.e. no motion detected within a certain period) => Alarm message:
„Emergency call due to sensor-1“. Therefore you have to activate time-out as below.
5.1.2.1 How to program presence verification time-out
Time-out for presence verification is factory set to 24h. If there is no activation within this period, an alarm is triggered
after a pre warning period of 10 minutes (this period is indicated with a periodical loud beep tone).
1. Shift function switch to PROG
2. Enter *. 9. 7. 1. 3 6 7 #. #. .
Current register value <n> will be announced followed by “to modify press *., to stop press #.
3. If you want to keep current value proceed with step 4. Otherwise modify register with *. New value <n> #..
The new register value <n> will be announced
4. Shift function switch to OFF
<n> Explanation
0 Presence verification is switched off (=Factory setting)
6..255 Time-out in steps of 10 min. (min. 60min, max. 42.5h) => For example: n=144 (144*10min = 24 h)
5.1.3 Sensor-1 as entry-detector (Gong function)
A sensor-1 activity can also be signalled locally (Gong-function) according to the following procedure:
Example: Sensor-1 shall greet an incoming person with the pre-recorded individual message only on position I.
1. Slide function switch to PROG
2. Enter sequence *. 9. 3. 1. 7 3 1 #. #...
Current register (bit 7 -> bit 0) will be announced followed by “to modify press *., to stop press #.
3. If you want to keep current value proceed with step 6. Otherwise start modifying register by pressing *..
4. Enter sequence 0. 0. 0. 0 1 1. 1. 0. .
Unused Gong on.. Gong-type
000: I / II / III 00: Gong
0 1 1 01: --
0: enabled 10: Individual message
1: disabled 11: Beep loud
5. Press key #. .
The new register (bit 7 -> bit 0) will be announced
6. Slide function switch to OFF
Factory default for sensor
-
1 monitoring
00 0 000 10, => un-delayed alarm in listening-in
connection only on all positions I/II/III
=> connector type: auto-type (plug&protect)
Factory default for gong
-
function sensor
-
1
000 111 00
Note:
If you do not want to
trigger an alarm on
position I you have to
disable alarm according to
section 5.1.1
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für EasyAlarm CONTROL wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von EasyAlarm CONTROL

EasyAlarm CONTROL Bedienungsanleitung - Deutsch - 32 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info