581260
6
Zoom out
Zoom in
Vorherige Seite
1/15
Nächste Seite
Pulsports-300/400
Pulsports-300/400
E10- -E11
HEART RATE FUNCTION
DESCRIPTIONS
1.Start /Stop heart rate measure function
1. Press P.MODE for 2 seconds to start heart rate measurement
function.
2. When the function is operating, the LCD will display the signal as
” and “ ”.
3. Press P.MODE for 2 seconds to stop heart rate measurement
function.
4. If a signal is not received for 5 minutes, the function will turn off
automatically.
2. Start/Stop heart rate data record function
1. Press ST/SP to start heart rate measurement function.
2. Press P.MODE to switch to EXE_TM function.
3. Press ST/SP, the signal shown as ” ” at the top right of the
display will change to “ , and this means the data record
function is started. Stop by pressing ST/SP, the signal will change
to “ “.
4. AVG, STW, CAL, EXE.TM, WT.LOS, FT.LOS, MAX, IN.TM,
OVR.TM, T_FT.L and T_CAL functions will only work while the
record function is on.
5. CAL/H and %FAT Loss will be displayed automatically when heart
rate is measured. The value will become “--“ while no pulse is
detected.
6. CAL, CAL/H, WT.LOS, %FAT Loss, FT.LOS and T_FT.L mode will
be calculated when the heart rate is equal or over 90 bpm.
3. Reset heart rate record data
1. Press P.MODE to switch to EXE_TM mode.
2. Press T.MODE for 2 seconds to clear the record.
3. T_CAL and T_F T. L record can only be erased under the original
function mode.
4. Heart rate display descriptions
1. Intensity = Current heart rate/Maximum heart rate.
2. Range of heart rate measurement is from 40 bpm to 240 bpm.
5. Program target zone mode (3 modes option)
Setup the target zone by entering the percentage of maximum heart
rate for the following 3 modes. Maximum heart rate based on the
data you input.
PRG
1. There are 3 mode of programmable target zones setup:
a). H: Switch the Target Zone manually.
b). T: Switch the Target Zone automatically according to the setup
time (0-99 minutes) for each zone; program will jump to the
next zone when the timer for the current zone is complete.
c). E: Switch the Target Zone automatically according to the setup
exercise time (0-99 minutes) for each zone; program will
jump to the next zone when the exercise time for the
current zone is complete.
2. The Beep alarm will sound when the target zone shifts from one
zone to another in auto-shift mode. It will beep for 10 seconds
when all target zones are complete, and END will be displayed.
3. In any zone, press T.MODE for 2 seconds for restart from the first
zone.
4. “ “ will display when the heart rate within the target zone.
5. ” “ will display when the heart rate is below the lower limit of the
target zone. (Beep should sound).
6. “ “ will display while the heart rate is above the upper limit of
target zone. (Beep should sound).
7.
a). Press P.MODE to select “PRG” mode.
Target zone program setting:
b). Press SET for 2 seconds to enter program target zone setting
mode.
c). Press T.MODE or ST/SP to choose the type of program.
d). Refer the Data Setting Processes
6. Stop watch mode
to adjust the Target zone
data. (Refer Fig .D)
1. Calculation of exercise time only works while a heart rate is
detected.
STW
2. The range is from 0 hr. 00 min. 00sec. to 99 hr. 59 min. 59 sec.
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Echowell Opal-400 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Echowell Opal-400

Echowell Opal-400 Bedienungsanleitung - Holländisch - 18 seiten

Echowell Opal-400 Bedienungsanleitung - Holländisch - 16 seiten

Echowell Opal-400 Bedienungsanleitung - Französisch - 15 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info