ENGLISH
INSTALLATION
GENERAL NOTES
In Italy it is necessary to refer to the standard declaration of
conformity conforming to Ministerial Decree 37/2008 (pur-
suant to Law 46/1990) and standards UNI 10683 and UNI
10412-2.
In the case of installation in a multiple-tenancy building, con-
tact the building manager before installation.
VERIFY COMPATIBILITY WITH OTHER DEVICES
In Italy the stove MUST NOT be installed in the same space
as type B gas heating equipment (e.g. gas boilers, stoves, and
equipment served by an extraction hood - ref. UNI 10683 and
7129).
In general, the stove could create low pressure in the room,
affecting the operation of such appliances or being affected by
them.
VERIFYTHE POWER SUPPLY CONNECTION
(the plug must be accessible)
The stove is supplied with a power cable that is to be connected
to a 230V 50 Hz socket, preferably tted with a magnetother-
mic switch.
Voltage variations exceeding 10% can damage the stove (unless
already installed, an appropriate differential switch must be
tted).
The electrical system must comply with the law; particularly
verify the efciency of the earthing system. The power line
must have a suitable cross-section for the stove’s power. An
inadequate earthing system can cause anomalies for which
Edilkamin cannot be held liable.
In case of problems with the electrical grid, consult an electri-
cian to evaluate the installation of a sine-wave UPS of at least
800 Va.
AIR INTAKE
The room where the stove is located must have an air intake
with cross section of at least 200 cm2 to ensurereplenishment
of the air consumed by combustion.
Alternatively, the stove air may be taken directly from outside
through a 8 cm steel extension of the pipe.
In this case,there may be condensation problems and it is ne-
cessary to protect the air intake with a grille, which must have
a freesection of at least 50 cm².
The pipe must be less than 1 metre long and have no bends.
It must end with section at 90° facing downwards or be  tted
with a wind guard. In any case all the way air intake duct must
be a free section of at least 50 cm².
The external terminal of the air inlet channel must be protected
with an anti-insect netting that does not reduce the 50 cm²
through passage.
POSITIONING AND DISTANCES FOR FIRE SAFETY
The stove must be installed in compliance with the following
safety conditions:
- minimum distance from ammable materials around the sides
and back of the stove: 20 cm
- ammable materials must not be placed less than 80 cm from
the front of the stove.
If it is not possible to comply with the above-mentioned di-
stances, technical and construction-related provisions must be
taken to prevent re hazards.
If connected to wooden walls or other ammable materials, the
smoke exhaust pipe must be insulated.
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Edilkamin Demy wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Edilkamin Demy

Edilkamin Demy Bedienungsanleitung und Installationsanweisung - Deutsch - 28 seiten

Edilkamin Demy Bedienungsanleitung und Installationsanweisung - Holländisch - 28 seiten

Edilkamin Demy Bedienungsanleitung und Installationsanweisung - Französisch, Italienisch - 52 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info