10. Technical data
Model designation CH 4000 E
Model Comfort Heater
Ignition High-voltage ignition
Power Alternating current 230 V – 50 Hz
Fuse 250 V – 5 amp / 250 V – 630 mA
(Use 2 fuses 2EA)
Fuel type Petroleum
Fuel tank capacity 4.6 liters
Fuel consumption (g/h) 183 - 317 g/h
Filament wattage (watts/KW) 2,200 – 3,800
Continuous operation 14 – 26 hours
External dimensions of heater 590 x 470 x 770 mm (Height, Depth, Width)
Weight 13.5 kg
Accessories Hand-held suction pump
Safety features Automatic cut-out, power failure fuse, overhea
cut-out, 3-hour cut out device, fuse for insuffici
combustion, automatic cut-out for excessively
high room temperature, over-voltage cut-out, fu
warning
Electricity consumption Intensive combustion – 36 watts
11. Description of functions
No. Function Description
1 Timer Preprogramming of the time or of the time when you
return home. If started with the timer the heater
switches itself off automatically after 1 hour of
operation. Before setting the timer you must first se
current time. The timer flickers once the button has
been pressed.
2 3 hour operation Used when 3 hour operation is required. Insert the
mains plug and press the button for 3 hour operatio
The display will show 3 hour operation. By pressing
3 hour button during operation, you can extend the
operation time by a further 3 hours
3 ON display Press this button when you require continual operat
See operating instructions also.
Ȝ If the air in the room is heavy then ventilation m
be necessary once or twice per hour.
4 Room temperature display This shows the room temperature. The display show
levels from 0 – 40° C. All levels below 0° C are show
by 00 and those above 40° C with 40.