GB
28
No. Designation of the Description
safety feature
6 Power and oxygen The fuse switches off because of lack of power, falling off o
shortage fuse the flame and insufficient oxygen. The display will show E0
and VENT. The fuse can be deactivated by pressing the OF
button.
7 Excessive rise in room The heater will stop operating if the room temperature rises
temperature above 30° C. The display will show E14. The room
temperature fuse is at the back of the heater. The fuse can
deactivated by pressing the OFF button.
8 Overheating fuse for In the event of overheating the burner will be turned off by t
high burning temperatures thermostat in the burner. The display will show 05. To
deactivate the fuse, pull out the mains plug and reinsert. To
cool the burner down, let the fan motor run for 2 minutes.
9 Oil supply alarm The alarm will be triggered when the remaining liquid fuel in
the supply tank is lower than the minimum level. The heate
will switch from high to low output and stop after 40 minute
The display will show E07 – FUEL. To cancel the alarm, pr
the OFF button, fill up the receiver tank and restart. If the ro
temperature has fallen below 30° C, operate the heater at f
burning output.
10 Fan protection device If the fan speed is slower than the set speed, insufficient
combustion will result. The heater then stops and the displa
will show E12. Press the OFF button to deactivate the
protection device.
11 Problem with combustion – The speed of the fan motor is abnormal or the temperature
operation stopped combustion is lower than the set level. The display will show
E08. Press the OFF button to deactivate the fuse.
12 Non-ignition fuse This stops combustion, because no flame was recognized
the length of the flame was too short.
The display will show E09.
Press the OFF button to deactivate the fuse.