3. Proper use
The air-conditioning system is only designed
to air-condition dry rooms. The room volume
depends on the local conditions. Large window
areas, additional heat sources (PC, television,
people, etc.), poor wall insulation, etc. serve to
reduce this room volume.
The equipment is to be used only for its
prescribed purpose. Any other use is deemed to
be a case of misuse. The user / operator and not
the manufacturer will be liable for any damage or
injuries of any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
4. Before starting the equipment
Before you connect the equipment to the
mains supply make sure that the data on the
rating plate are identical to the mains data.
Always place the portable device on a firm,
horizontal footing.
The machine must always be in an upright
position.
Never tilt the device by more than 45°!
Whenever the device has been transported
(inclined positions), leave for at least one
hour before connecting to a socket outlet.
In the cooling function the warm exhaust air
must be transferred outside by the exhaust air
hose. An opening in the wall or window must
therefore be provided.
Please note that the minimum distance bet-
ween the equipment and the wall to the side
50 cm and rear must be 50 cm. The minimum
distance to other objects at the front must be
2 m.
4.1 Installing the activated charcoal filter
(Fig. 4)
1. Take out the filter frame
2. Remove the filter fastener from the filter frame
3. Take the carbon filter out of the bag
4. Place the carbon filter in the filter frame
5. Fasten the filter with the filter fastener
6. Slide in the filter frame
4.2. Installing the exhaust air hose (Fig. 5)
Use only the supplied exhaust air hose. The
length of the exhaust air hose can be varied from
between 500 mm to 1500 mm. For the most
effective cooling the hose should be as short as
possible. Avoid kinks are excessive bends in the
hose so that the exhaust air can be transferred
out without hindrance. If you ignore this advice,
the device as a whole may overheat and shut
down. This could result in damage to the device.
Warning!
The length of the exhaust air hose is matched
to the technical specifications of the device.
Never extend the hose as this could lead to
malfunctions or faults on the device.
Under certain circumstances a partial vacuum
may develop in the room, which will lead to a
reduction in the cooling performance of the
device. To prevent this from happening you must
ensure that there is a supply of air to the room
(leave the door to the room slightly open).
Fitting the exhaust air hose through an open
window (Fig. 6)
Secure the exhaust air hose to the connection
opening for the exhaust air hose by turning it
clockwise.
Use the exhaust air adapter for the window
and the extendible window adapter. Fasten
the air adapter for the window to the exhaust
air hose by turning it clockwise. Open the
window slightly and clamp the window
adapter in the gap. Secure the window so
that the window adapter is kept firmly in
place. Insert the exhaust air adapter for
the window in the opening provided in the
window adapter.
Accessory:
Hot Air Stop Art.-Nr.: 23.651.50
Note: Take appropriate precautions to prevent
unauthorized entry through the window.
Fitting the exhaust air hose through the wall
We recommend that you use a suitable telescopic
duct with automatic shutter and wall connection
(available at your DIY store) to which you can
connect the hose without using the exhaust air
adapter for the window.
Anleitung_MK_2100_E_SPK7.indb 21Anleitung_MK_2100_E_SPK7.indb 21 25.09.2018 10:12:4125.09.2018 10:12:41
21

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Einhell MK 2300E wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info