Check the mains lead at regular intervals for
signs of defects or damage. A damaged mains
lead may only be replaced by an electrician or
ISC GmbH in compliance with the relevant
regulations.
CAUTION!
Read all safety regulations and instructions.
Any errors made in following the safety regulations
and instructions may result in an electric shock, fire
and/or serious injury.
Keep all safety regulations and instructions in a
safe place for future use.
Packaging:
The unit is supplied in packaging to prevent it from
being damaged in transit. The raw materials in this
packaging can be reused or recycled.
Tips on saving energy
Only use the air conditioner when you really need to.
Do not select too high a temperature for heating or
too low a temperature for cooling. Select the “Sleep”
function during the night.
Close all windows, doors and Venetian blinds in
order to reduce incoming sunlight as far as possible.
Principle of operation for cooling
Heat is extracted from the air in the room by the air
heat-exchanger (evaporator) in which the coolant
circulates. This air is conveyed to the outside air
heat-exchanger (condenser).
This gives off heat to the outdoor air. Electrical
energy is required for this. In certain circumstances
condensation may form on the evaporator on the
indoor unit, which will be removed by the
condensation hose.
2. Items supplied
SKA 2503 EQ C+H
1 indoor device (box 1, art. no. 23.654.14)
1 outdoor device (box 2, art. no. 23.654.15)
1 set of installation accessories (for details, see page
19)
SKA 3503 EQ C+H
1 indoor device (box 1, art. no. 23.654.16)
1 outdoor device (box 2, art. no. 23.654.17)
1 set of installation accessories (for details, see page
19)
3. Technical data
SKA 2503 EQ C+H
Cooling capacity 2600 watts
Heating capacity 2800 watts
Energy efficiency B (EER 3.09/COP 3.33)
Air capacity 410 m
3
/h
Absorbed humidity 1.0 l/h
Timer 24 h
Operating voltage 220 - 240 V ~ 50 Hz
Socket fusing 16 A
Nominal power consumption, cooling 840 watts
Nominal current consumption, cooling 3.7 A
Nominal power consumption, heating 830 watts
Nominal current consumption, heating 3.7 A
Compressor Rotary piston
Compressor starting current 22 A
Outdoor temperature, cooling operation °C
+18 - +43 (DB)
Outdoor temperature, heating operation °C
-7 - + 24 (DB)
Fluid line Ø A 6.35 mm
Suction pipe Ø A 9.53 mm
Length of refrigerant line supplied 4 m
Length of refrigerant line, max. 10 m
Max. difference in height between indoor/outdoor
device 5 m
Refrigerant R 410 A
Refrigerant filling capacity 730 g
Refrigerant refill quantity from 5 m 20 g/m
Sound pressure level
Inside ≤ 39 dB (A)
Outside ≤ 53 dB (A)
Dimension Inside 79 x 27,5 x 19 cm
Dimension Outside 78 x 54 x 25 cm
Weight Inside 8,5 kg
Weight Outside 28 kg
SKA 3503 EQ C+H
Cooling capacity 3300 watts
Heating capacity 3600 watts
Energy efficiency B (EER 3.14/COP 3.42)
Air capacity 620 m
3
/h
Absorbed humidity 1.2 l/h
Timer 24 h
Operating voltage 220 - 240 V ~ 50 Hz
Anleitung_SKA_2503_E+Q_C_H_GB:_ 10.12.2008 11:28 Uhr Seite 12
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Einhell SKA 3503 EQ C-H wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Einhell SKA 3503 EQ C-H

Einhell SKA 3503 EQ C-H Bedienungsanleitung - Deutsch - 32 seiten

Einhell SKA 3503 EQ C-H Bedienungsanleitung - Holländisch - 32 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info