GB
13
Socket fusing 16 A
Nominal power consumption, cooling 1050 watts
Nominal current consumption, cooling 4.9 A
Nominal power consumption, heating 1050 watts
Nominal current consumption, heating 4.9 A
Compressor Rotary piston
Compressor starting current 33 A
Outdoor temperature, cooling operation °C
+18 - +43 (DB)
Outdoor temperature, heating operation °C
-7 - + 24 (DB)
Fluid line Ø A 6,35 mm
Suction pipe Ø A 12,7 mm
Length of refrigerant line supplied 4 m
Length of refrigerant line, max. 10 m
Max. difference in height between indoor/outdoor
device 5 m
Refrigerant R 410 A
Refrigerant filling capacity 840 g
Refrigerant refill quantity from 5 m 25 g/m
Sound pressure level
Inside ≤ 43 dB (A)
Outside ≤ 54 dB (A)
Dimension Inside 79 x 27,5 x 19 cm
Dimension Outside 78 x 54 x 25 cm
Weight Inside 9 kg
Weight Outside 35 kg
Note:
The specified capacities and performances are
based on the following conditions (EN 14511):
Cooling:
Air temperature at the inlet on the indoor device:
27°C for dry thermometer bulb (DB), 19°C for wet
thermometer bulb (WB). Outdoor air temperature:
35°C for dry thermometer bulb (DB), 24°C for wet
thermometer bulb (WB).
Heating:
Air temperature at the inlet on the indoor device:
20°C for dry thermometer bulb (DB), 15°C for wet
thermometer bulb (WB). Outdoor air temperature:
7°C for dry thermometer bulb (DB), 6°C for wet
thermometer bulb (WB).
Temperature ranges:
Cooling
Room temperature 17°C ~ 32°C
Outdoor temperature 18°C ~ 43°C
Heating
Room temperature 17°C ~ 30°C
Outdoor temperature -7°C ~ 24°C
Dehumidifying
Room temperature 17°C ~ 32°C
Outdoor temperature 18°C ~ 43°C
Notes:
1. For health reasons the room temperature should
be no more than 5 – 6°C below the outdoor
temperature in cooling mode.
2. The perfect performance of the system is
achieved within the temperature ranges shown in
the table.
3. If the air conditioning system is operated below
the temperature range shown above, protection
functions may be activated in certain
circumstances which will cause the device to
operate abnormally.
4. If the air conditioner is operated in a relative
humidity level of over 80%, condensation may be
deposited on the top of the system which will
then drip on to the floor. In this case set the
horizontal air flap to its maximum angle
(perpendicular to the floor) and set the FAN to
“HIGH”.
4. Intended use
The SKA 2503 EQ C+H air-conditioning system is
only designed for air-conditioning privately used dry
rooms with a maximum room volume of 80 m
3
(SKA
3503 EQ C+H is suitable for a maximum room
volume of 110 m
3
). The room volume depends on the
local conditions. Large window areas, additional heat
sources (PC, television, people, etc.), poor wall
insulation, etc. serve to reduce this room volume.
The machine is to be used only for its prescribed
purpose. Any other use is deemed to be a case of
misuse. The user / operator and not the
manufacturer will be liable for any damage or injuries
of any kind caused as a result of this.
Please note that our equipment has not been
designed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial