741484
18
Zoom out
Zoom in
Vorherige Seite
1/20
Nächste Seite
(((ELKRON)))
MP110 USER MANUAL
(((ELKRON)))
MP110 USER MANUAL
3.6 Disarming with Antirobbery Code
If the system is equipped with an integrated telephone unit or other remote
transmission system, a panic alarm signal can be sent in case of constraint
to disarm the antirobbery system.
The disarming procedure described in para 3.1 is carried out, but it is
necessary to enter the secret code increasing the last digit by one unit.
Example: code 123456 would become 123457; code 132459 would
become 132450.
Disarm the control unit; if within approx.30 sec the correct code is not
entered the control unit will send the panic alarm to all programmed
telephone numbers.
3.7 Wrong Code
In case of introduction of a wrong code for 4 consecutive times, the
system visualizes a tamper on the keypads and the readers. When
introducing a wrong code for the fifth consecutive time, the system starts
a tamper alarm.
3.3 Arming with Reduced Code
It is sufficient to enter the first 2 digits of the code followed by key
TOTAL
for a total arming, or
1
,
2
or
3
for a partial arming.
Quick arming is possible only if the system is fully disarmed.
3.4 Commutating Lock with Open Zones
If the commutating lock with open zones has been programmed, it will
not be possible to arm –neither from keypad nor by DK key – the sectors
to which the currently open zones are associated. If you try such an
arming from keypad, a relevant warning is provided on the display and
no arming will take place.
3.5 Open Zone Self-Bypassing
If both commutating lock and self-bypassing have been programmed,
the zones left open are automatically bypassed when an arming from
keypad or DK key is carried out. If the arming is made from keypad, the
self-bypassing is properly signalled on the display. The arming regularly
takes place and no alarm is generated. The self-bypassed zones are
reentered automatically at their re-closing (even with armed system).A
following opening will therefore generate the alarm.
23
Indicates the presence of the mains
voltage and the level of battery charge:
OFF = 220V~ mains absent
FIXED LIGHT = 220V~ mains present
FLASHING = Insufficient battery charge
These display the status of the 3 zones
into which the alarm system is divided:
ON = armed zone
OFF = disarmed zone
These Leds flash to indicate the presence
of events to be displayed, see paragraph
5 “Display of System Status”
Keys used to arm/disarm the system (see
par. “System Arming/Disarming”). These
are also used to scroll the programming
menu.
Keys used to type the secret code and to
select certain functions on the alarm unit
programming menu.
SYSTEM MANAGEMENT BY KEYPAD
WITH SEGMENTED SCREEN
KP100
1.Keypad Description
A flashing light indicates that alarms have occurred.
A flashing light indicates that burglaries have occurred on one or
more parts of the system.
A flashing light indicates that there are some protected zones (doors
or windows protected by contacts) that are still open.
A flashing light indicates that some sensors/contacts are disabled.
TOTAL
ZONE
TEL
EXIT
SIREN
123
A
12
45
7
3
6
9
F
0
8
C
S
O
E
**
3
2
1
3
KP100
+
-
18
18

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Elkron MP110 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Elkron MP110

Elkron MP110 Bedienungsanleitung - Deutsch - 32 seiten

Elkron MP110 Bedienungsanleitung - Französisch - 120 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info