7. System Test
- Enter the access MASTER code.
- Press key
F
+ key
3
. All leds turn on. A 30s delay is armed
during which the system test is carried out.
- By pressing kei
SIREN
1
, you access the alarm siren test and all allarm
actuator can be tested for 5s. To stop the alarm, press
SIREN
1
again
or
EXIT
F
.
- By pressing key
ZONE
3
, you access the input test procedure, any alarm
memory is turned off and a 10min delay is armed , after which you
automatically quit the test.
- After arming the test procedure, the sensor effectiveness can be tested
by means of the WALK-TEST (you walk in front of the sensor). The
display will show the number of the sensor in alarm, while the buzzer will
generate a sound for 5 seconds.
- If you walk in front of a “disabled” sensor, it is visualized on the display
but the buzzer will generate no sound. This means that a disabled input
is only stored but generates no alarm.
- By pressing key
EXIT
F
from procedure, then it is possible to see the
tested inputs resulted effective by means of the stored alarm visualiza-
tion procedure (key
A
+ key
1
) .
NOTE:
The test phase is signalled on all keypads and all commutators of the
plant by means of appropriate indications on the displays and the slow
flashing of the 3 sector leds.
8.Telephone Number Programming
1. Enter MASTER USER access code
2. Press key
EXIT
F
+
TEL
9
+
O
in sequence.
3. The display visualizes the first programmed telephone number: “Tn:
nnnn——n” (if there is no programmed telephone number, there will be
empty characters).
4. To go to other available numbers, if any, use keys
1
and
2
.
13
The display will show the characters “ ” flashing to show the
introduction of the year.
Enter a value from 00 to 99 (2 digits).
To confirm and store the entered date, press key
F
.
The system carries out no control on the consistency of the entered
data; the operator shall therefore ascertain that the programmed day/
month data are correct before confirming. In case of correct data, the
new date is stored and the positive result of the operation is confirmed
by an OK beep. When quitting by timeout, the modification is not saved
7. System Test
Enter the access MASTER code.
Press key
F
+ key
3
. All leds turn on while any alarm memory
turns off. A 30s delay is armed during which the system test is carried
out.
By pressing key
SIREN
1
, you access the alarm siren test and all alarm
actuators can be tested for 5s. To stop the alarm , press
SIREN
1
again
or
EXIT
F
.
By pressing key
ZONE
3
, you access the input test procedure, any alarm
memory is turned off and a 10min delay is armed , after which you
automatically quit the test.
After arming the test procedure, the sensor effectiveness can be tested
by means of the WALK-TEST (you walk in front of the sensor). The
display will show the number of the sensor in alarm, while the buzzer will
generate a sound for 3 seconds.
If you walk in front of a “disabled” sensor, it is visualized on the display
but the buzzer will generate no sound. This means that a disabled input
is only stored but generates no alarm.
By pressing key
EXIT
F
from procedure, then it is possible to see the
tested inputs resulted effective by means of the stored alarm visualiza-
tion procedure (key
A
+key
1
) .
28
13

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Elkron MP110M wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Elkron MP110M

Elkron MP110M Bedienungsanleitung - Deutsch - 32 seiten

Elkron MP110M Bedienungsanleitung - Französisch - 120 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info