4. When setting temperature Hi or Lo value, press [ ALARM ] key to toggle the alarm
on/off of the regarding HI / LO alert.
5. When nished, press and hold [ ALERT ] key for 2 seconds or without pressing keys
for 60 seconds to return normal mode.
High humidity alert on
High temperature alert on
Note:
- You cannot enter conicting HI / LO values in the setting. For example, if the HI
temperature alert value is 40°C, you cannot enter more than 39.9°C for the LO alert,
and so forth.
- When the alert is triggered, the alarm will sound and the alarm icon on the display will
ash. Press [ ALARM / SNOOZE ], [ ALARM ] or [ ALERT ] key to stop the alarm
sound. If you ignore the alarm, it will stop after 2 minutes.
- When auto-cycle mode, if any alarm is triggered the display will switch to the regarding
channel. You can press [ ALARM / SNOOZE ], [ ALARM ] or [ ALERT ] key or leave
the unit for 2 minutes to stop the alarm. The display will return to auto-cycle mode
afterwards.
MOON PHASE
The main unit can show the northern hemisphere moon phase status, below is the table
which illustrate how the moon will appear on the main unit
Northern hemisphere Moon Phase
New Moon
Waxing Crescent
First quarter
Waxing Gibbous
Full Moon
Waning Gibbous
Third quarter
Waning Crescent
LOW BATTERY ICON
If the main unit or sensor is low in battery, the low battery icon “ ” will display. The icon
will only appear when the corresponding channel is displayed.
For example, the sensor of CH 1 is low in battery. When CH 1 is displayed, the icon “
” will show.
Note:
The batteries in main unit are only for backup purpose, the battery life cannot maintain
for long time usage.
IMPORTANT NOTE
- Read and keep these instructions.
- Do not subject the unit to excessive force, shock, dust, temperature or humidity.
- Do not cover the ventilation holes with any items such as newspapers, curtains etc.
- Do not immerse the unit in water. If you spill liquid over it, dry it immediately with a
soft, lint-free cloth.
- Do not clean the unit with abrasive or corrosive materials.
- Do not tamper with the unit’s internal components. This invalidates the warranty.
- The socket outlet shall be installed near the equipment and shall be easily accessible.
- Only use fresh batteries. Do not mix new and old batteries.
- Do not dispose old batteries as unsorted municipal waste. Collection of such waste
separately for special treatment is necessary.
- Attention! Please dispose of used unit or batteries in an ecologically safe manner.
- Technical specications and user manual contents for this product are subject to
change without notice.
Hereby, Emos spol. s r. o. declares that the radio equipment type ESW5002 is
in compliance with Directive 2014/53/EU. The full text of the EU declaration of
conformity is available at the following internet address:
http://www.emos.eu/download
SPECIFICATIONS
MAIN UNIT
Dimensions (W x H x D) 202 x 138 x 38mm
Main power DC 5V, 500mA adaptor
Backup battery 3 x AAA size 1.5V batteries
(Alkaline battery recommended)
Barometer range 540 to 1100hPa, 405 to 825mmHg, 15.95 to
32.49inHg
Operating temperature range -5°C to 50°C ( 23°F to 122°F )
Humidity range RH 1% to 99 %
Resolution of temperature 0.1°C/°F
Resolution of humidity 1%
Radio controlled signal Received from wireless sensor
Number of sensors support Up to 8 units
WIRELESS SENSOR
Dimensions (W x H x D) 61 x 113.6 x 39.5mm
Main power
2 x AA size 1.5V batteries
(Lithium battery recommended for low temperature
environment)
Operating temperature range -40°C to 60°C ( -40°F to 140°F )
Operating humidity range RH 1% to 99 %
RF frequency 433MHz
RF transmission range 30 meters
Radio controlled signal DCF
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für EMOS SELECT 5002 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info