INSTALLATION
The appliance must be installed by qualified staff working in
accordance with the installation regulations in force.
Before installing, ensure that the appliance is correctly preset
for the local distribution conditions (gas type and pressure).
The presettings of this appliance are indicated on the label shown
on the cover.
This appliance is not connected to a flue gas extractor device.
It must be installed and connected in accordance with the
regulations in force. This appliance may only be installed and
operate in rooms permanently ventilated in accordance with
national regulations in force.
ROOM VENTILATION
The rooms in which gas appliances are installed must be well
ventilated in order to allow correct gas combustion and
ventilation.
The airflow necessary for combustion is at least 2 m
3
/h for each
kW of rated power.
POSITIONING (fig. 3)
Remove the hob from the packaging accessories, including the
films covering the chrome-plated and stainless steel parts. Place
the hob well away from items of furniture with sides higher than
the built-in hob. In addition, any separating wall parallel to the
work surface must be at least 1 cm below the hob casing, and
an opening 10 cm square must be provided underneath the gas
hose elbow. You are advised to make the gas connection before
positioning the hob in the supporting unit.
FIXING
A self-adhesive gasket (A) is supplied with the hob, and must
be placed under the edge of the box unit, as close as possible
to the edge itself (fig. 4). The gasket must fit all the way round
for a perfect seal, preventing moisture from getting beneath the
hob. Place the appliance in the hole in the hob, making sure
that the adhesive gasket provides a firm seal between the edge
of the hob and the surface of the unit (fig. 5), and adjust the
hooks already inserted in the casing (fig. 6).
CONNECTING TO THE GAS SUPPLY
Before connecting the hob, check that it is preset for the gas to
be used. The connection to the appliance is made on the left. If
other heating devices nearby mean there is a risk the hose may
overheat to above 30°C (e.g. if the line passes above another
appliance) a rigid pipe must be used.
Use of a rigid pipe (fig. 7) is compulsory for operation with natural
gas.
CONNECTING TO THE ELECTRICAL MAINS
Before making the connection, check that:
- the mains voltage is as indicated on the nameplate
- the earth connection is in good working order.
If the socket is not easily accessible, the installation engineer
must provide a switch with contact breaking gap of 3 mm or
more.
If the appliance power lead is not fitted with a plug, use an
approved standard type, remembering that:
- the green-yellow wire must be used for the earth connection;
- the blue wire is the neutral;
- the brown wire is live;
- the lead must never touch hot surfaces over 75°C;
- replacement leads must be of type H05RR-F or H05V2V2-F
of suitable size (see fig. 2) for gas and all-electric appliances,
and of type FR3R3 of suitable size (see fig. 2) for mixed
appliances;
- the power supply lead must only be replaced by a qualified
technician.
IMPORTANT: the manufacturer declines all liability for damage
due to failure to comply with the regulations and standards in
force.
Check that the appliance is correctly connected to the earth (see
fig. 2).
FOR HOBS WITH ELECTRIC IGNITION
The correct gap between the electrode and the burner is shown
in figure 9.
If no spark is generated, do not keep on trying as this might
damage the generator. Possible causes of malfunction:
- spark plug damp, dirty or broken;
- electrode-burner gap not correct;
- spark plug wire broken or without sheathing;
- spark discharging to earth (to other parts of the hob);
- generator or microswitch damaged;
- air has built up in the pipes (particularly if the hob has been out
of use for a long time),
- air-gas mixture incorrect (poor fuel setting).
IMPORTANT
- Before carrying out any work inside the appliance, disconnect
the mains plug and shut off the gas tap.
- Never use matches to check for gas circuit for leaks. If a specific
control device is not available, foam or very soapy water can
be used.
- When re-closing the hob, check that the electric wires of the
spark plugs (if present) are not close to the injectors, so that
they cannot run across them.
GB Installation
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Etna EN036V wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info