-Technical menu: the technical menu is reserved for the cooker stove installer.
-Alarms: in this section of the menus is displayed any ongoing alarm. The alarm can be disabled by pressing the buttons P1 andP4. Alarm deletion is confirmed
by a long beep. The alarms are:
•Sensor 1 open: the sensor is not connected.
•Sensor 1 short-circuit: the sensor is damaged.
•Sensor 2 open: the sensor is not connected.
•Sensor 2 short-circuit: the sensor is damaged.
•H2O level sensor failure: if the sensor does not switch off within a given period of time T after the tank is fed with water,due to boiling or any other reason,
the stove enters the H2O level sensor failure alarm condition.
•Hot water: the temperature of the water inside the boiler exceeded the maximum threshold.
Installation with Contact (external thermostat):
For the version with contact (valid for diagram 2,3,4): the display shows the temperature of the boiler. When the contact opens, the display shows T OFF and output
V2 is powered. When the contact closes, the display shows T ON.
EXAMPLE:
When the contact opens because the boiler requires hot water, the three-way valve switches towards the boiler and the display shows T OFF. Once the stove
meetsthe water requirement, the contact closes and the display shows T ON.
Installation with Probe:
For the version with sensor (valid for diagram 2,3,4): the display shows the boiler temperature and the measured temperature alternately. The sensor is adjusted
by T3. Therefore, if the temperature measured by the sensor is below T3, output V2 is enabled. If the temperature measured bythe sensor is above T3, the 3-way
valve returns to its stand-by position.
EXAMPLE:
If the temperature measured by the sensoris lower than T3, a 3-way valve is enabled and it switches towards the boiler. If the temperature measured by the sensor
is above T3, the 3-way valve returns to its stand-by position.
04.2 IGNITION
CHECKS BEFORE START-UP
After connecting the stove to the hydraulic system and the electrical system you need to:
•Fill the system slowly, with the cap of the automatic release valve open. The system must be filled slowly so as to allow anyair bubbles to come out of
the stove exchangers.
•If necessary, bleed the radiators.
•Fill the boiler tank: you can use a container or wait for it to be filled by means of the automatic fill valve (after 5 minutes of operation of the automatic
valve, the display might show the H2O LEVEL SENSOR FAULT alarm. Reset the alarm by pressing buttons P1 and P4 at the same time).
•The water should cover the exchangers but it should not exceed the limit of the discharge pipe.
•Do not start the stove if the tank is empty: you will not be able to heat your home and you also might damage the stove.
To light the cooking stove, small (dry) logs and possibly ecological fire-lighters are required. Open the primary air register located on the front of the ash drawer
and place the wood logs. After positioning the logs, place the fire starters belowthe wood and light them up. Close the door and wait for the flame to reach all the
wood logs. Good ignition depends very much on the draught of your flue pipe: if the ignition is difficult, the flue pipe willnot have the recommended draught due to
the fact that it is cold and the stove will require more time to reach the intended operating conditions. In this case, we recommend that you open the ash drawer or
keep the fire door slightly open. Make sure the internal fume diverter/register (if provided) is open (turn counter-clockwise).
CAUTION:
Never use flammable liquids to ignite the wood logs. Also, after turning the stove on, keep in mind to close the primary air register. If you fail to close it, the stove
might overheat and might get damaged. Also, the paint might still be fresh and it might release intense odours. Therefore, you should make sure that the room is
properly ventilated before igniting the stove for the first time. Open the doors and windows to remove any odours from the room. The product might also suffer
slight deformations asits structure is made of steel; therefore you might hear slight noises or crunches. This is absolutely normal and should not be considered a
defect.
The display is off during the ignition phase. It will turn on once the temperature of the water inside theboiler exceeds 30°C.
Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.
Art des Missbrauchs:
Forenregeln
Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:
Lesen Sie zuerst die Anleitung;
Schauen Sie nach, ob die Frage bereits gestellt wurde;
Stellen Sie die Frage so deutlich wie nur einigermaßen möglich;
Erwähnen Sie was Sie bereits versucht haben um das Problem zu lösen;
Ist Ihr Problem von einem Besucher gelöst dann lassen Sie ihn / sie wissen in diesem Forum;
Falls Sie reagieren möchten, so verwenden Sie bitte das Antworten- Formular;
Da ihre Frage für alle Besucher sichtbar ist, sollten Sie lieber keine persönliche Daten erwähnen.
Neu registrieren
Registrieren auf E - Mails für Eva Calor Wanda wenn:
neue Frage gestellt werden
neue Handbücher vorhanden sind
Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.
Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.
Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.
Ihre Frage wurde zu diesem Forum hinzugefügt
Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.