695872
27
Zoom out
Zoom in
Vorherige Seite
1/36
Nächste Seite
27ENGLISH
AUX
If the producer's conveyed wave accessories are used, the connection must be made by the qualied technician directly in the board.
Contact the dealer for further details
LCD HANDHELD REMOTE ROOM PROBE CALIBRATION
This mode allows calibration of the room temperature detected by the LCD handheld remote (with ventilation active only). For correct
calibration, it is recommended to position the LCD handheld remote in a room with constant temperature and wait for at least two hours.
Below nd the calibration procedure:
Access the menu and reach TECH MENU”.
Set the access key "F4". - "ADJ REMOTE PROBE"
Use the
OK
or
OK
keys to adjust the desired room calibration.
Save and exit via the
OK
key.
ADDITIONAL THERMOSTAT
N.B. : Installation must be performed by an authorised technician
It is possible to thermostat a room adjacent to the room where the stove is positioned: just connect a thermostat following the procedure
described in the next step (it is recommended to position the optional mechanical thermostat at a height of 1.50 m from the oor) . Stove
operation with external thermostat connected in the clamp TA can be dierent on the basis of activation or deactivation of the STAND
BYfunction.
By default, the clamp TA exits jumpered, therefore it always has closed contact (on request).
ADDITIONAL THERMOSTAT FUNCTIONING WITH STANDBY ACTIVE
When the function is activated, STBY will be shown on the display. When the contact or external thermostat is not satised (open contact
=temperature reached), the stove will switch o. As soon as the contact or external thermostat switches to the "not satised" status (closed
contact / temperature to be reached) it will re-ignite.
Nota bene: stove operation depends on the temperature of the water inside the stove and relative factory setting restrictions. If stove
is in HOFF (water temperature reached), any additional contact or thermostat request will be ignored.
ADDITIONAL THERMOSTAT OPERATION WITH STANDBY DEACTIVATED
When the contact or external thermostat is satised (open contact / temperature reached), the stove will go to minimum. As soon as the contact
or external thermostat switches to the "not satised" status (closed contact / temperature to be reached) it will start to work again at the pre-set
power.
Nota bene: stove operation depends on the temperature of the water inside the stove and relative factory setting restrictions. If stove
is in HOFF (water temperature reached), any additional contact or thermostat request will be ignored.
ADDITIONAL FUNCTIONS
ADDITIONAL THERMOSTAT INSTALLATION
Switch the appliance o using the master switch positioned on
the rear of the stove.
Remove the plug from the socket.
Connect the two cables of the thermostat to clamp (TA),
positioned on the rear of the machine.
DEPRESSURE NOTICE
It allows to activate the warning buzzer if the door or hopper is open.
Please note: activating this buzzer may reduce battery life by 30%.
Battery life depends on use.
To set: OK>SETTINGS>DEPRESSURE NOTICE
27

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Extraflame Fiandra Idro wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Extraflame Fiandra Idro

Extraflame Fiandra Idro Bedienungsanleitung - Deutsch - 36 seiten

Extraflame Fiandra Idro Bedienungsanleitung - Französisch - 36 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info