J
FOR CORRECT OPERATION, SET TO AUX.
> SEE THE INSTALLATION CHAPTER SUPPLEMENTARY THERMOSTAT
STAND BY FUNCTION SET TO ON
If the STAND BY function is enabled (ON) and the room temperature exceeds the SET THERMOSTAT + DELTA T OFF value, then the stove
switches o after a preset factory delay, and STAND BY will be displayed on the screen.
When the room temperature is lower than the SET THERMOSTAT - DELTA T ON value, and after a possible cooling time, the stove switches
back on.
STAND BY FUNCTION SET TO OFF FACTORY SETTING
If the STAND BY function is not active (OFF), if the stove exceeds the set room temperature it will switch to the minimum value, modulating
and displaying MODULATION. When the room temperature is lower than the SET THERMOSTAT the stove will restart at the set power and
WORK will be displayed on the screen.
OPERATION WITH ADDITIONAL THERMOSTAT OPTIONAL
STAND BY FUNCTION SET TO OFF FACTORY SETTING
If the STAND BY function is not active (OFF), if the stove exceeds the room temperature set on the additional thermostat (open contact) it will
switch to the minimum value, displaying MODULATION. When the room temperature is lower than the set value on the additional thermostat
(closed contact), the stove will resume operation at the set power, and WORK will be displayed on the screen.
STAND BY FUNCTION SET TO ON
When the STAND BY function is activated (ON), when the room temperature set on the additional thermostat is reached (open contact), the
stove will switch o after a preset delay, and STAND BY will appear on the screen.
When the room temperature is less than the set temperature on the additional thermostat (closed contact), and after a certain cooling time,
the stove ignites again.
J
WHEN STAND BY AND AIR ZONE CONTROL ARE ACTIVE, THE GENERATOR IS SWITCHED OFF ONLY IF BOTH ROOMS
INSTALLATION, DUCTING REACH THE SET TEMPERATURE.
SETTINGS
• DATETIME
• LANGUAGE
• DEGREES
See chapter: firSt ignition SettingS
DISPLAY
This menu allows you to adjust the brightness of the display. The values range from OFF, 1 to 20. If set to OFF, the display backlighting is set
to maximum brightness and turns o after a 60 second delay.
The backlighting can be turned on again by pressing any key or if the stove is in the alarm condition.
CONTROLS PROCEDURE
Press key 6.
Press key 3 until SETTINGS appears and conrm by pressing key 6.
Keep pressing key 3 until DISPLAY appears and conrm by pressing key 6.
Use keys 4-5 to set the desired intensity.
Press key 6 to conrm and key 1 to scroll back through the menus until the initial page.
STAND BY
The STAND BY function is used if the stove needs to be turned o immediately instead of a power modulation.
CONTROLS PROCEDURE
Press key 6.
Press key 3 until SETTINGS appears and conrm by pressing key 6.
Keep pressing key 3 until STAND BY appears and conrm by pressing key 6.
Use keys 4-5 to enable (ON) / disable (OFF).
Press key 6 to conrm and key 1 to scroll back through the menus until the initial page.
21

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Extraflame Sabry 5.0 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Extraflame Sabry 5.0

Extraflame Sabry 5.0 Bedienungsanleitung - Deutsch - 32 seiten

Extraflame Sabry 5.0 Bedienungsanleitung - Holländisch - 32 seiten

Extraflame Sabry 5.0 Bedienungsanleitung - Französisch - 32 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info