Ferm 43
3. USE
BEFORE STARTING THE GENERATOR
Ground terminal
The generator ground terminal is
connected to the frame of the generator,
the metal non-current-carrying parts of
the generator, and the ground terminals
of each receptacle. Before using the
ground terminal, consult a qualified
electrician, electrical inspector or local
agency having jurisdiction for local
codes or ordinances that apply to the
intended use of the generator.
Fill and check oil level (quantity is 600 ml)
Always check the oil level (with machine in a
level position) before starting and if the engine
unexpectedly stops (fig. 2).
For general use you can use an “all
temperature” oil 10W-30
≤ 0ºC SAE#10
0ºC - 25 ºC SAE#20
25ºC - 35 ºC SAE#30
≥ 35ºC SAE#40
Fill and check fuel level
• Use unleaded fuel only
• Remove any power cords
• Turn power switches off
• Do not overfill – leave air gap at top of fuel
level
• Always screw down fuel cap
• Clean up any spilled fuel
• Do not smoke while operating the
generator
Always use caution!
Starting the generator
Fig. 1 + 4 + 5
1. Turn on fuel tap (15).
2. Turn on engine switch (12).
3. Move choke lever (13) to closed position
(to restart a warm engine, leave the choke
lever in open or half-open position).
4. Pull slowly on the starter cord until it
engages, then pull sharply to start the
engine (14).
5. Allow the engine to run until it warms up,
and then move the choke lever to the open
position (13).
Using the AC Output (230 V)
• Start the generator.
• Plug in the electrical appliance plug.
• Press AC current protector downward to
“ON”(7).
• The voltmeter (11) displays the voltage on
the AC socket. Normally this should be ±
230 V during use.
Stopping the generator
Fig. 1 + 5
1. Unplug all cords (5)
2. Turn engine switch to “OFF” (12)
3. Turn off fuel tap (15)
4. SERVICE & MAINTENANCE
PERIODIC MAINTENANCE
Daily (pre-operation check)
• Check engine oil level
• Check fuel hose for cracks or other
damage. Replace if necessary.
• Check exhaust-system for leakage.
Retighten or replace gasket if necessary.
• Check choke operation
• Check recoil starter operation
1st Month or 20 hrs
• Replace engine oil
3 Months or 50 hrs
• Check condition of spark plug. Adjust gap
and clean. Replace if necessary.
• Clean, replace if necessary.
6 Months or 100 hrs
• Replace engine oil
• Clean fuel tap and fuel tank filter. Replace if
necessary.
• Check fittings and fasteners. Replace if
necessary.
12 Months or 300 hrs
• Contact a specialized service centre to
check the valve clearance.
6 Ferm