• Remove the air filter cover (16).
• Remove filter element and wash well in
solvent.
• Pour a small amount of oil onto the filter
element and gently squeeze out any excess
oil.
• Replace the filter element and air filter cover.
• Be sure the filter cover seals properly all
around.
Do not run the engine without the air filter
element in place.
Never place a wet filter (with solvent) on
the machine.
Fuel tap
• To remove the fuel tap filter, simply undo the
cup at the bottom of the fuel tank
• Use a small spanner to remove the tap
• Clean and wash out the filter and cup, and
replace.
Troubleshooting
Basic checks
• Make sure you have plenty of fuel
• Make sure the fuel tap is on
• Make sure the engine-switch is on
• Make sure the oil level is correct
• The generator has an oil sensor. When the oil
level is too low, the generator will not be able to
start.
• Remove spark plug, connect spark plug lead
and earth it to the generator. Pull starter cord
gently and look for a spark. If there is no spark,
replace spark plug.
Spark plug is OK, but engine still won’t start
• Check fuel tap filter is clean
• Check fuel line is clear
• Check carburetor is not clogged
Engine will not start
• Clean or replace spark plug
• Check ignition system – if faulty, contact your
service centre
• Check compression – if low, contact your
service centre
• Check for loose cylinder head – tighten bolts
• Check for damaged cylinder head gasket –
replace if necessary
Cleaning
Clean the housing regularly with a soft cloth,
preferably every time it is used. Keep the air vents
free of dust and dirt.
Remove stubborn dirt with a soft rag moistened in
soapy water. Do not use any solvents such as
petrol, alcohol, ammonia, etc. as such substances
can damage the plastic parts.

• Drain fuel tank, fuel tap, carburetor bowl and
carburetor
• Pour 1 cup of engine oil into the fuel tank and
shake the generator to spread the oil around
the tank. Drain excess oil.
• Remove spark plug and pour in 1 spoonful of
engine oil, pull the starter cord several times
with the starter switch OFF. Replace spark
plug.
• Pull on the starter cord until you feel
compression and stop.
• Clean the generators exterior and coat with
rust inhibitor.
• Place the generator on flat ground and cover
with a clean dry cloth.
Faults
Should a fault occur, e.g. after wear of a part,
please contact the service address on the warranty
card. In the back of this manual you find an
exploded view showing the parts that can be
ordered.
Environment
To prevent damage during transport, the appliance
is delivered in a solid packaging which consists
largely of reusable material. Therefore please
make use of options for recycling the packaging.
Faulty and/or discarded electrical or
electronic apparatus have to be collected
at the appropriate recycling locations.

Do not dispose of power tools into domestic waste.
According to the European Guideline 2012/19/EU
for Waste Electrical and Electronic Equipment
and its implementation into national right, power
tools that are no longer usable must be collected
separately and disposed of in an environmentally
friendly way.

Read the terms of warranty on the separate
warranty card which is enclosed.
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Ferm PGM1012 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info