Observe the following
when extracting
dust generated by operating electric power
tools:
If the exhaust air is discharged back into the
room, the
air renewal rate L
within the
room must be sufficient. The volume of air
discharged back into the room must not ex-
ceed 50% of the fresh air volume flow (room
volume V
R
x air renewal rate L
W
). Observe all
the relevant regional regulations.
Remember:
A moist main filter clogs more
quickly when extracting dry materials.
Therefore, dry the main filter before extract-
ing dust or replace the damp filter with a dry
one.
8.3 Extracting fluids
Before extracting fluids, remove the filter
bag (see Chapter 7.8). We recommend using
a special wet filter.
The dust extractor stops automatically when
the maximum level is reached.
8.4 After finishing work
X
Switch off the mobile dust extractor and
disconnect the plug.
X
Wind up the mains power cable.
X
Empty the dust container.
X
Only CTM 48 E LE EC:
Close off the ex-
tractor opening [1-2] using the sealing
plug [1-1].
The machine shall be stored indoors
only.
X
Place the mobile dust extractor in a dry
room inaccessible to unauthorised users.
9 Service and maintenance
Damaged safety devices and components
must be repaired or replaced in a recognised
specialist workshop, unless otherwise indi-
cated in the operating manual.
Observe the following instructions:
A dust test must be performed at least
once a year by the manufacturer or an in-
structed person. This test may include
checks to determine whether the filter is
damaged, the machine is sealed properly
and the monitoring features are function-
ing correctly.
During maintenance and repair work, all
components that cannot be cleaned satis-
factorily must be replaced. The old compo-
nents must be sealed in impermeable
plastic bags prior to disposal in compliance
with applicable regulations for this type of
waste.
Provided maintenance personnel or other
persons in the vicinity are not endangered,
the user must dismantle and clean the ma-
chine prior to performing maintenance
work. Appropriate precautionary measures
include decontaminating the machine prior
to disassembly, making provisions for lo-
cally filtered forced ventilation at the loca-
tion of machine disassembly, cleaning the
maintenance area and appropriate person-
al protective equipment.
CAUTION
Escaping foam and fluids
X
Switch off the machine immediately and
empty the dirt trap.
WARNING
Hazardous dust
Damage to the respiratory passage
X
Wipe down the mobile dust extractor and
clean all accessories thoroughly using the
extractor (inside and out) before removing
from the working area.
X
Parts that you were not able to clean thor-
oughly must be sealed in an airtight plastic
bag prior to transportation.
X
Wear a dust mask!
WARNING
Risk of injury, electric shock
X
Always disconnect the mains plug from the
socket before performing maintenance
work on the machine!
X
All maintenance and repair work which re-
quires the motor housing to be opened
must only be carried out by an authorised
service workshop.
17

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Festool CTL 48 E LE EC wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info