15
7. [TIMER]
Programmable time switch with start and residual time
Starting time
: This function is used to switch on the unit automatically when the time entered has
expired. Proceed as follows:
i) Press [TIMER] switch in Stand-by (this unit is connected but not in operation), to enter the required
number of hours after which the unit is to start.
ii) Select the required function (cooling, heating, dehumidification) and set the required temperature.
iii) When the set number of hours has expired, the unit starts automatically.
If you press the [POWER] switch before the time has expired, the time programming is deleted. The
unit switches on and can be operated in the required operating mode.
Residual time: This function is used to automatically deactivate the unit when the time entered has
expired. Proceed as follows:
i) Press the [TIMER] switch during operation and enter the required number of hours after which the
unit is to switch off.
ii) After the flashing of the number of hours on the LED has stopped, you can select the required
function (cooling, heating, dehumidification) and the required temperature.
iii) When the set number of hours has expired, the unit switches on automatically.
If you press the [POWER] switch before the time has expired, the Timer programming is deleted and
the unit switches off.
8. [SLEEP]
Using this key you can set the sleep function of the unit. The microprocessor integrated in the unit
will raise the pre-set temperature by 2°C per hour up to a maximum of 4°C after 2 hours and maintain
this temperature until the set time has expired..
If you use the sleep function, first set the time switch to the set hours as described in the functions
Residual time or Starting time. Then press the [TIMER] switch until the required hours appear on the
display. After the hour display, the display switches automatically to the previous set temperature
display. To change the temperature, press the switch [TEMP+] or [TEMP-]. With each press on the
switch, the temperature increases or decreases by 1°C.
COOLING
It is recommended to start the unit early on hot days, thus avoiding heating up of the room.
This unit has a self-evaporation function for condensation water, so that it is normally not necessary to
empty the water tank in cooling mode. The drainage hose need not be connected. Please make sure that
the outlet is closed with the rubber cap during operation.
(This does not apply in the case of high air humidity. If the unit operates in cooling mode for a longer period and especially at a time
of year with high air humidity, the condensation tank may be full. The control lamp will remind you to empty the water. Refer to error
message E4. In such a case, empty the water tank via the condensation water outlet. If continuous high air humidity is likely, it is
recommended to drain the condensation continuously via the drainage hose.)
COOLING IN INDOOR OPERATION
The unit stands in the room to be cooled.
Connect the air hose and the air outlet grid to the unit as displayed in the illustration; the air hose
connection piece and air outlet grid need to be exchanged.