INTRODUCTION
fully configurable with the same features as the
wirefree zones.
ZONE LOCKOUT
If a detector on an active zone is triggered while the
system is armed an alarm condition will occur. After
the programmed alarm duration has expired the
alarm will stop and the system will automatically
reset. Subsequent detectors triggered will again
initiate an alarm condition. If a single zone initiates
an alarm condition more than three times then that
zone will be ‘Locked Out’ and any further alarm
signals from that zone will be ignored until the
system is disarmed.
Note: The ‘Zone Lockout’ feature can be disabled if
required.
QUICK SET
The system may be fully armed in 5 seconds using the
quick set facility, overriding the programmed exit-
delay. This is useful for setting the system at night
when the exit-delay warning beep will be silenced
after just a few seconds.
FINAL EXIT SET ZONE
Triggering a detector on a Final Exit zone during the
exit-delay will cause the delay to reset to 5 seconds
with the system arming 5 seconds later.
WALK THROUGH ZONE
This feature may be used to temporarily disable
detectors on zones covering the route between the
main entry door and the Control Panel.
If the system is armed and the property is accessed via
the “Entry-Door” zone then the setup entry-delay will
operate as normal. However all “Entry-Route “ zones
will be disabled to allow free access to the Control
Panel to Disarm the system before the entry-delay on
the “Entry-Door” zone expires an alarm occurs.
If the first zone triggered is the “entry-route” zone then
the system will operate according to the zones normal
configuration.
Notes:
The zone configured as the “Entry Door” must
be setup with an Entry-Delay sufficient to reach
the Control Panel and Disarm the system.
Zones configured as the “Entry Route”
should be setup without an Entry-Delay.
OMIT ZONE
A zone may be temporarily omitted when the system
is armed using the Omit feature. When the system is
next disarmed any zones set to Omit will be cancelled.
EVENT LOG
The Control Panel incorporates a memory capable of
storing the last 50 system events. This enables the
user to see which user has Armed/Disarmed the
system and if and when any alarms occurred. The
time, date and details of the event type will be
recorded for each system event.
CHIME
Chime is a low security facility for use when the
system is Standby mode. If the Chime feature is ON,
and a detector on a zone that has its Chime function
enabled is triggered, the internal sounder will produce
a low volume warning tone. A typical use of the Chime
function would be to warn that a door or particular
area has been accessed.
VOICE DIALLER
This system incorporates a telephone voice dialler
that is used to call for help and/or notify the user that
the system has been triggered and an alarm has
occurred.
If the Voice Dialler is enabled and an alarm condition
occurs, the system will call for help using your
recorded alarm message and up to four telephone
numbers. When the telephone voice dialler is
activated it will call the first enabled number in the
dialling sequence and replay the recorded alarm
messages for the configured ‘Play Time’. The
recipient must acknowledge the message by pressing
the button on their telephone keypad. If the
call is unanswered or an acknowledgment signal is not
received then the next active number in the dialling
sequence will be called. The dialler will continue
calling each number in turn until either all numbers in
the sequence have been dialled the set number of
times or the dialling sequence is cancelled by an
acknowledged signal from the recipient.
REMOTE MANAGER
As an alternative to the Voice Dialler the system may
be configured to interface direct with an Alarm
Monitoring Service using the Ademco Contact ID
communications protocol.
SA54
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Friedland SA5 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info