747972
20
Zoom out
Zoom in
Vorherige Seite
1/27
Nächste Seite
20
Expert Gyro and Governor Definitions and Tuning Section
*It does not display, when Opr.
mode is Gyro+THR, and when
SWASH-type is H4-00/H4-45.
*It does not display, when Opr.mode is
Gyro+THR, and when SWASH-type is
H4-00/H4-45.
*It does not display, when Opr.mode is
Gyro+THR, and when SWASH-type is
H4-00/H4-45.
G
OVERNOR
E
XPERT
S
ETTING
7KLVPHQXVHWVWKH*RYHUQRU([SHUWDOORZVWKHXVHUWRIXUWKHUUH¿QHWKHJRYHUQRUVHWWLQJV3XVKWKHPRGHRU±NH\IRUPRUHWKDQRQHVHFRQGRQWKH
*RYHUQRU%DVLFPHQXGLVSOD\WRJHWLQWRWKH*RYHUQRU([SHUWPHQX3XVKPRGHRU±NH\IRUPRUHWKDQRQHVHFRQGDJDLQRQWKH*RYHUQRU([SHUW
PHQXWREHUHWXUQHGWRWKH*RYHUQRU%DVLFPHQX
GOVERNOR EXPERT
MAP
(1) Governor Expert setting: start display
Push mode + or – key, to scroll through the editing menu. Pushing mode + or – key for more than
one second, brings you back to governor basic menu.
(2) Governor working mode [default: Governor]
Sets the governing type mode.
- Governor Mode – RPM is entirely controlled by the GOV once it has engaged. The GOV will do
whatever it takes to hold a constant RPM throughout flight.
- Limiter Mode – Throttle control follows the throttle curves to advance the throttle position during
flight, but controls the RPM during throttle reduction by not letting the RPM over speed past the
set RPM.
(3) Rv. Display [default: Rotor]
Ability to choose to display desired ROTOR RPM or MOTOR RPM.
(5) Yaw Comp [default: CW/TOP]
Yaw compensation allows the governor to more rapidly correct for changes in power demands of
the model resulting from yaw input. Set the mode to match the gyro installing direction, either CW/
TOP, CW/BOTM, CCW/TOP, CCW/BOTM by pushing the Set key. Pushing the RSET key inhibits
the function.
At the governor only mode, this parameter is inhibited.
CW: clockwise rotor direction
CCW: counter clockwise rotor direction
TOP: Gyro top/name emblem facing up
BOTM: Gyro top/name emblem facing down
(4) Feed Forward from Cyclic [default: 0%]
Increasing the value will add throttle with cyclic commands to aid in RPM stability.
(6) Revolution change up delay [default: 8] [ranges: 2 ~ 20]
How quickly the RPM changes when increasing RPM between two different RPM conditions and
flight modes. A higher number slows the RPM change rate; a lower value speeds up the RPM
change rate.
(7) Revolution down delay [default: 10] [ranges: 2 ~ 20]
How quickly the RPM changes when reducing RPM between two different RPM conditions and
flight modes. A higher number slows the RPM change rate; a lower value speeds up the RPM
change rate.
Push
DATA
+/– key
Push
MODE
+/– key
(8) Start delay [default: 5] [ranges: 2 ~ 20]
How quickly the RPM stabilizes to the set RPM from when the GOV is turned ON. A higher value
slows down the spool up rate; a lower value speeds up the spool up rate.
*It does not display, when Opr.mode is
Gyro+THR, and when SWASH-type is
H4-00/H4-45.
F/F.Cycl
0 %
Push
DATA
+/– key
Rv.Disp
Rotor
Rv.Disp
Engine
*It does not display,
when Opr.mode is
Gyro+THR, and
when SWASH-type
is H4-00/H4-45.
(9) Low revolution setting [default: 1000 rpm ]
This value is set to assign the lowest possible governing RPM. If the RPM is set below, or cannot
reach this RPM, the governor will not engage.
(10) Governor data reset
This parameter resets also the governor parameters to default settings. The “Exec.??” is displayed
by pushing data + or – key for confirmation. Pushing data+ or -key again completes the reset pro-
cess, displays “-Exec.-”, and returns to the start display. By pushing mode+ or – key during confir-
mation display, the reset process is aborted.
Push
DATA
+/– key
Push
DATA
+/– key
20

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Futaba CGY750 V 2.0 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info