Electrical safety
1. It is recommended that you use a Residual
Current Device (R.C.D.) with a tripping current of
not more than 30mA. Even with a R.C.D.
installed 100% safety cannot be guaranteed and
safe working practice must be followed at all
times. Check your R.C.D. every time you use it.
2. Before use, examine cable for damage, replace it
if there are signs of damage or ageing.
3. Do not use the product if the electric cables are
damaged or worn.
4. Immediately disconnect from the mains electricity
supply if the cable is cut, or the insulation is
damaged. Do not touch the electric cable until
the electrical supply has been disconnected. Do
not repair a cut or damaged cable. Take the
product to an Authorised Service Centre and
have the cable replaced.
5. Always make sure that the cable/ extension cord is
kept behind the user, ensuring that it does not
create a source of danger for the user or for other
persons, and check that it cannot be damaged (by
heat, sharp objects, sharp edges, oil, etc);
6. Position the cable so that it will not be caught on
branches and the like, during cutting.
7. Always switch off at the mains before
disconnecting any plug, cable connector or
extension cable.
8. Switch off, remove plug from mains and examine
electric supply cable for damage or ageing
before winding cable for storage. Do not repair
a damaged cable. Take the product to an
Authorised Service Centre and have the cable
replaced.
9. Remove the plug from the mains before leaving
the product unattended for any period.
10.Always wind cable carefully, avoiding kinking.
11.Use only on AC mains supply voltage shown on
the product rating label.
12.The chainsaw is double insulated to EN60745-1
& 2-13.
Cables
1. Mains cables and extensions are available from
your local Approved service centre
2. Only use approved extension cables
3. Extension cables and leads should only be used
if they are designed for outdoor use and comply
with H07 RN-F or IEC 60245 designation 66.
Use only 1.0mm2size cable up to 40m in length
maximum
C. SAFETY EQUIPMENT DESCRIPTION
SWITCH BLOCK
Your machine is equipped with a device (fig.1a, 2a)
that when deactivated, stops the switch from being
pressed thus preventing accidental start-up.
CHAIN BRAKE ACTION ON SWITCH RELEASE
Your machine is equipped with a device that blocks
the chain immediately as soon as the switch is
released; If this device should not work at any time,
the machine must NOT be used and must be taken
to an Authorised Service Centre.
FRONT HAND GUARD / CHAIN BRAKE LEVER
The front hand guard (fig.1b, 2b) is designed to
prevent your left hand from coming into contact with
the chain (on condition that the machine is held
correctly according to instructions). The front hand
guard also acts as a chain brake, including a device
that stops the chain in less than 0.15 of a second in
the case of kickback. The chain brake is released
when the front hand guard is pulled backwards and
clicked in position (fig.3a, 3b). The chain brake is
activated when the front hand guard is pushed
forward and the chain is stopped (see ON-STOP
indication) (fig.4a, 4b). The chain brake can be
activated using the left wrist by pushing forwards, or
when the wrist comes into contact with the front
hand guard as a result of kickback.
When the machine is used with the bar in horizontal
position, for example during tree felling, the chain
brake offers less protection.(fig.5).
N.B.: When the chain brake is activated, a safety
switch cuts off all current to the motor.
Releasing the chain brake whilst the switch
is held will start the product.
CHAIN CATCHER
This machine is equipped with a chain catcher (fig.6a, 6b)
located under the sprocket. This mechanism is designed
to stop the backward chain movement in the case of
chain breaking or derailing. These situations can be
avoided by ensuring correct chain tension (Refer to
chapter “D. Assembly/disassembly”).
REAR HAND GUARD
This acts to protect (fig.7a, 7b) the hand in the case
of chain breaking or derailing.
THERMAL CUT-OUT
The Motor is protected by a Thermal Cut-Out Switch
(fig 1c, 2c) which is activated when the chain
becomes jammed or if the motor is overloaded.
When this occurs, stop and remove the plug from
the power supply, clear any obstruction and wait for
a few minutes for the product to cool down. Reset
by pushing back in the Thermal Cut-Out Switch.
Resetting the Thermal Cut-out Switch with the
chain brake released and the switch held will
start the product.
ENGLISH - 5
15

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gardena CSI 4020-X-8863 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Gardena CSI 4020-X-8863

Gardena CSI 4020-X-8863 Bedienungsanleitung - Deutsch - 21 seiten

Gardena CSI 4020-X-8863 Bedienungsanleitung - Holländisch - 21 seiten

Gardena CSI 4020-X-8863 Bedienungsanleitung - Französisch - 21 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info