1. GENERAL
1.1 Installation and servicing must be carried out by a
competent person in accordance with Gas Safety
(Installation and Use) Regulations 1998, the relevant
British Standards for Installation, appropriate Codes of
Practice and in accordance with the manufacturers
instructions. It is recommended that a CORGI registered
engineer be used for this purpose as they are approved
by the HSE under the above regulations.
1.2 This appliance is suitable for use in G.B. and I.E. using
Natural Gas at a supply pressure of 20mbar or LPG at a
supply pressure of 29mbar (Butane) or 37mbar (propane).
1.3 The installation shall also be completed in accordance with:
– The Building Regulations issued by The Department of
The Environment.
– The Building Standards (Scotland) Regulations issued by
the Scottish Development Department.
For Republic of Ireland, reference should be made to the
relevant standards governing installations (IS813:1996)
1.4 Read all these instructions before commencing installation.
1.5 This appliance must be installed in accordance with the
rules in force and only used in a sufficiently ventilated
space.
1.6 Ensure that curtains are not positioned above the stove, and
that there is at least a clearance of 300mm between the
sides of the stove and any curtains.
1.7 The manufacturer considers the full outer casing of this
stove to be a working surface. Therefore it will become hot
whilst in operation. A suitable guard is recommended to
protect young children, the aged and the infirm.
1.8 This stove must only be operated with the door secured
firmly in position. If any cracks appear in the glass the
appliance must not be used until the glass panel is replaced.
1.9 Do not attempt to burn rubbish in this stove.
1.10 Any combustible shelves or surrounding furniture must only
be fitted in accordance with the minimum dimensions
detailed in diagram 1.
1
AR1468
1.11 Contact a competent service engineer to carry out relevant
spillage checks etc. following home improvements carried
out after installation of this stove (e.g. the fitting of double
glazing).
1.12 In all correspondence, please quote the appliance type and
serial number which can be found on the databadge at the
rear of the stove.
1.13 This product is guaranteed for 2 years from the date of
installation, as set out in the terms and conditions of sale
between Gazco and your local Gazco dealer. Please consult
with your local Gazco dealer if you have any questions. In
all correspondence always quote the model No. and serial
No. Please ensure the commissioning checklist is
completed by your installer, as this is a requirement of
your Guarantee.
2. LIGHTING THE STOVE
2.1 Locate the control valve on the appliance. There are two
control knobs on the valve, the right-hand knob controls the
pilot ignition and the left-hand knob controls the main
burner.
2.2 If your appliance has already been upgraded to battery
remote control, please refer to the instructions provided with
the upgrade to operate the remote control. The following
instructions will work for either situation.
2
AR0914
2.3 Ensure that the left-hand control knob is pointing to off ( )
2.4 Ensure that the right-hand control knob is pointing to off ( ).
2.5 Press in the right-hand control knob and rotate it anti-
clockwise until a click is heard (keep pressing in) and the
knob is pointing to pilot ( ). The pilot should now light. If
the pilot has not lit, repeat the procedure until it does.
2.6 Keep the control knob pressed in for 10 seconds and then
release it, the pilot should stay alight. If the pilot goes out,
repeat the procedure until does.
2.7 If the pilot will not light after repeated attempts, contact the
retailer or installer from whom the appliance was purchased.
2.8 Turn the right-hand control to point to main burner ( ) .
The appliance can now be controlled using the left- hand
control knob.
2.9 Turn the left-hand control knob to point to low fire ( ) the
main burner will light on low. The burner can now be
controlled between low and high settings. Turn the control
knob anti-clockwise to increase the flame height and
clockwise to decrease the flame height.
THE YELLOW FLAMES WILL APPEAR WHEN THE FIRE
HAS GAINED SUFFICIENT HEAT - TYPICALLY 10 TO 20
MINUTES.
IF THE APPLIANCE IS EXTINGUISHED OR GOES OUT IN
USE, WAIT 3 MINUTES BEFORE ATTEMPTING TO
RELIGHT THE APPLIANCE.
4
USER INSTRUCTIONS
4

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gazco F40 Avanti Conventional Coal wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info