3.5 EXTRA FLUE LENGTHS
All flue components are 150mm diameter (6")
NOMINAL
LENGTH ACTUAL
LENGTH STAINLESS
FINISH ANTHRACITE
FINISH
200mm 140mm 8527 8527AN
500mm 440mm 8528 8528AN
1000mm 940mm 8529 8529AN
40° Bend N/A 8507 8507AN
90° Bend N/A 8508 8508AN
NOTE: The following areas need careful consideration:
a) Terminal positions
b) Flue supports
c) Weatherproofing
d) Fire precautions
For all the above options, local and national codes of practice
must be adhered to.
CONVENTIONAL & BALANCED FLUE
4. GAS SUPPLY
4.1 Before installation, ensure that the local distribution
conditions (identification of the type of gas and pressure)
and the adjustment of the appliance are compatible.
4.2 Ensure that the gas supply is capable of delivering the
required amount of gas and is in accordance with the rules
in force.
4.3 Soft copper tubing can be used to install the appliance. Soft
soldered joints can be used externally of the appliance but
must be restricted to the area shown in Diagram 2.
4.4 This appliance is supplied complete with a factory fitted
isolation device incorporated into the inlet connection, no
further isolation device is required.
4.5 All supply gas pipes must be purged of any debris that may
have entered, prior to connection to the appliance.
4.6 The gas supply enters through the silicone panel located on
the RH side of the outer box; this will need to be slit with a
sharp knife prior to passing the supply pipe through.
5. VENTILATION
5.1 This appliance requires no additional ventilation.
15
INSTALLATION INSTRUCTIONS
SITE REQUIREMENTS - CONVENTIONAL & BALANCED FLUE
6. APPLIANCE LOCATION
6.1 With the exception of the F67 Riva (see below), it is not
necessary to site these products on a non-combustible floor.
However, for practical reasons, the floor should be flat and
solid to allow the appliance to be levelled and secured in
place.
6.2 This appliance may be situated anywhere in the room, but
due consideration should be taken to ensure that it is sited
within the constraints of the allowable flue configuration.
6.3 As well as allowing for the flue position, you must also
consider the position of bench and the F67 upon the
bench.
6.4 If the appliance is to be sited against a combustible wall, a
clearance of 50mm should be allowed between the wall
and the rear of the appliance.
6.5 F67 Riva
The F67 Riva requires a non-combustible hearth.
A non-combustible hearth must be at least 12mm thick and
project 50mm from the base of the stove in all directions.
The minimum dimensions are shown in Diagram 2.
2
AR0604
MINIMUM CLEARANCE
A = 980 mm
B = 520 mm
C = Minimum 12 mm
6.6 F67 Riva Pedestal & F67 Riva Bench
6.6.1 The Riva Pedestal or the Riva Bench does not need a
non-combustible floor but the appliance must not be
fitted on a carpet. Use a solid floor.
6.6.2 These two appliances can be situated anywhere in the
room but when siting you must consider the constraints
of the flue.
6.6.3 If the appliance is to be sited against a wall, a clearance
of 50mm must be allowed between the wall and the
appliance.
15

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gazco Riva F67 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info