ALARM MEMORY
When disarming the alarm, if five turn signal flashes and five beep signals
occur, it is possible to identify the cause generating the alarm condition.
To do this, turn the ignition key to “ON” position and look at the vehicle installed
LED.
The LED will be blink, shown the last alarm condition.
The cause of the alarm will indicate for 10 times, and this indication can be
interrupted by turning the ignition “OFF”.
The possible alarm signalling are indicated in the table below.
LED SIGNAL CAUSE OF THE ALARM
NUMBERS OF
ALARM CYCLES
10
10
10
10
10
10
Volumetric sensor
Doors/boot switches
Positive under key (+15/54)
Absorption sensor
External magnetic contact
Bonnet switch and
volumetric sensors
LED ON (400mS)LED OFF (2 seconds)
NEUTRAL TIME
SYSTEM ARMED AFTER NEUTRAL TIME
EVENTS THAT CAN GENERATE AN ALARM CONDITION
NOTE:
ALARM DISARMING
At the end of each alarm cycle there is a neutral time period, lasting up to
approx. 5”, during which there will be no reaction to the causes of alarm. During
the neutral time between successive alarms, the LED will emit a continuous
light. Normal flashing will be resumed at the end of the neutral time.
At the end of the neutral time (approx. 45”), the security system is completely
armed and ready to intervene in cases of attempted theft or sabotage.
Completely armed status is indicated by the flashing of the LED, which will
work according to the following timing scheme in order to minimise power
consumption:
LED ON : 200mS
LED OFF : 2”
System wire cutting by means of the self-powered siren
Attempt to start the engine.
Attempt to open the doors.
Attempt to open boot.
Attempt to open engine bonnet.
Intrusion detected by internal ultrasound volume sensor.
Intrusion detected by external sensors (option,also by radio).
Panic alarm by pressing key no. 2 on the remote (this function is active
only if enabled in the accessory function programming phase and it can be
used only in countries where the law permits this type of alarm activation
not available in product version for the dutch market).
In order to filter noise and/or undesired signals, the POSITIVE UNDER
KEY, DOORS and BOOT PUSH-BUTTON inputs have a DEBOUNCE time of
200mS. Therefore these inputs will cause the generation of an alarm cycle only
if the signals coming in last longer than 200mS.
For every input and every arming cycle, the alarm causes are limited to 10
cycles of 30 seconds each.
The alarm system can be deactivated by pressing key 1 on the remote, by
inserting the electronic key into the appropriate receptacle.
Disarming is indicated by three turn signal flashes and three acoustic signals.
If an alarm condition has occurred, it will be signalled by five turn signal flashes
and five acoustic signals (if these functions have not been excluded in
programming stage).
See next paragraph for all signalling.
!
!
!
!
!
!
!
!
NOTE:
SUPPLEMENTARY SIREN OPERATION
ORIGINAL HORN OPERATION
NOTE:
the cause of alarm of CUT WIRE does not enabled the alarm memory
because it is managed by the external self-powered siren.
Continuous audible signal for the entire duration of the alarm signal cycle.
Intermittent sound 2” ON 2” OFF for the entire duration of the alarm signal
cycle.
If the user has cut out the siren, the alarm condition will be indicated solely by
the flashing of the turn indicators for a maximum time period of 30”.
While the alarm signal is given out, the LED will emit a continuous light.
You can cut off the alarm cycle without deactivating the system, by pressing
key no. 2 on the remote. As you do so, the audible/visible alarm signals will be
immediately cut off, and the system will switch to the condition of NEUTRAL
TIME BETWEEN SUCCESSIVEALARMS.
To minimise acoustic pollution, the DOORS PUSHBUTTON, BOOT
PUSHBUTTON, BONNET PUSHBUTTON, ELECTRICAL INPUT SENSOR,
INTERNAL VOLUME SENSOR and EXTERNAL SENSORS inputs are
subject to a limitation of up to ten alarm cycles per system activation period.
The count is reset upon the next deactivation of the alarm system or if an alarm
for POSITIVE POLE UNDER KEY intervenes during the same activation
cycle.
PAGE 5
PAGE 4
3

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gemini 7590T2-1 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info