11.0 - SYSTEM PROGRAMMING
The t
E
able below applies to the system programmed in “standard configuration”.
very time you enter the programming procedure, the alarm resets to the default settings.
FUNCTION STATUS LED FLASHES
Disabled
Enabled
Disabled
Disabled
Disabled
Enabled
Disabled
-----
Exclusion of arming/disarming optic signalling
Exclusion of arming/disarming acoustic signalling
System passive arming
Arming of self-powered coded siren
Doors input - positive
Optical pulse signalling
Negative output during alarm cycle
For Gemini only, turn ignition key
PAGE 12 - INSTALLER MANUAL INSTALLER MANUAL - PAGE 13
11.7 -
).
NEGATIVE OUTPUT SELECTION (DURING ALARM) FOR HORNS OR ADDITIONAL
SIREN
Once activated, this function can activate the output for the siren (continuous tone) or for the horn
(intermittent tone
If the function is disabled, under normal operating conditions, the blue wire carries a negative signal;
during an alarm cycle, there is a lack of negative.
12.0 - SYSTEM PROGRAMMING EXAMPLE
.
Here below is an example that illustrates the various steps to follow to modify the programmable
functions.
As mentioned before, every key rotation disables a function, while the electronic key enables it.
When ignition is turned On or Off or the electronic key is touched to its receptacle, a high or low pitched
signal sounds and the LED flashes according to table in chapter 11.0
In both cases, system moves on to the next function.
signals
Repeat steps above to enable or disable other functions.
When the last function is programmed (either with the electronic key or the ignition key), in
addition to the confirmation tone, the system gives two low-pitched and one high-pitched acoustic
and the turn indicators flash twice.
These last two signals indicate the end of the programming procedure.
With alarm system disarmed, turn ignition key “ON” and touch electronic key to
its receptacle.
ON
Two acoustic signals (a high and a low-pitched sound) and two flashes of the turn indicators
indicate that the system is in the programming procedure.
OFF-ON
Boop
Beep
Turn ignition “OFF” and then back “ON” to
disable the function.
A low-pitched acoustic signal confirms the
operation.
The LED flashes according to selected function
(from 1 to 8).
OR
Touch electronic key once to its receptacle to
activate the function.
A high-pitched acoustic signal confirms the
operation.
The LED flashes according to function the
selected function (from 1 to 8).
When the optical pulse signaling feature is activated, the blinkers will ONLY emit optical
signals during an alarm cycle.
The system BLUE wire MUST be connected to the Hazard push-button.
In this case, do not connect the ORANGE wires (see chapter 7.3)
!
Alack of power during electrical system maintenance, will not affect the programming.
The procedure must be carried out entirely because key rotation disables the selected function and
moves to the next one until the programming procedure is completed.
Programmable functions are briefly described below and the next paragraph illustrates the
programming instructions.
This function activates optic signals during system arming (1) and disarming (2).
11.1 - OPTICAL SIGNALS
If the vehicle already has optical locking/unlocking signals, the turn indicators alarm
flashes should be deactivated.
11.2 - ACOUSTIC SIGNALS
11.3 - PASSIVE ARMING
11.4 - ENABL
11.5 - DOOR SWITCH POLARITY SELECTION
11.6 - OPTICAL PULSE SIGNAL/SELF-POWERED SIREN
This function activates acoustic signals during system arming (1) and disarming (2).
.
(art. 7725).
This function modifies the alarm input signal (positive or negative) according to the signal generated
This function activates the optical
.
This function arms the system 60” after ignition is switched off and the last door is opened and closed.
If a door is opened during this lapse of time, the procedure is interrupted and it is resumed when the
door is closed
by the doors switch.
signals according to the connection made; only for vehicles where
hook-up is to the “emergency” push-button wire (Hazard push-button)
ING OF SIREN (7725) OUTPUT
This function enables the relative output (20-way connector, position 13, PINK wire) to activate the
self-powered coded siren
!
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gemini 933 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Gemini 933

Gemini 933 Bedienungsanleitung - Deutsch - 9 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info