10 GMC-I Messtechnik GmbH
Opening of Equipment / Repair
The equipment may be opened only by authorized service personnel to
ensure the safe and correct operation of the equipment and to keep the
warranty valid.
Even original spare parts may be installed only by authorized service per-
sonnel.
In case the equipment was opened by unauthorized personnel, no war-
ranty regarding personal safety, measurement accuracy, conformity with
applicable safety measures or any consequential damage is granted by
the manufacturer.
Meanings of Symbols on the Instrument
The symbols on the instrument have the following meanings:
Warning regarding dangerous electrical voltage
Warning concerning a point of danger
(Attention: observe documentation!)
Test socket
Indicates EC conformity
This device may not be disposed of with the trash. For further
details on the WEEE marking, please refer to our website
www.gossenmetrawatt.com and enter search term ’WEEE’.
2.1 Notes Regarding the High-Voltage Test
(only Feature F02 or SECULIFE ST
HV)
The KS13 cable set, or similar cable sets, may not be used for the high-voltage
test. The high-voltage test may only be performed directly via the test socket!
Attention!
!
Do not hold the device under test in your hand during testing,
especially when testing safety class II devices.
Make sure that the device under test does not make contact
with any equipment or persons during testing.
Liability Exclusion
In the event of sparkover, PCs operated in proximity to the test instrument may
“crash” resulting in data loss. All data and programs should be suitably backed up
before high-voltage testing is performed, and computers should be shut down if
necessary. A crash may occur even if no RS 232 connection has been established.
The manufacturer of the test instrument assumes no liability for direct or
consequential damage to computers, peripherals or data which occurs
during high-voltage testing.
The manufacturer assumes no liability for defects at the device under test
which result from high-voltage testing. As a rule, defects can only occur at
devices under test which are not in compliance with applicable standards,
which were previously damaged or which have been improperly repaired,
because high-voltage testing is required for type and routine testing by
IEC 61010-1/EN 61010-1 / VDE 0411, part 1, as well as EN 60335,
EN 60601 and EN 60950.
!
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gossen Metrawatt SECULIFE ST HV wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info