Reactivation of the statutory summer time period:
Press the S/W key twice!
The displayed AU summer time period (statutory) must be stored with the key S.
Switchover results in back-calculation and the switching outputs are updated in accordance with the program. See Point 4.3
Note:
On the date of the summer time/wintr time and winter time/summer time switchover, no switching commands may be
programmed between 02:00 and 03:00.
8. Programming as a week time switch – routine week program
The routine week program is automatically always assigned to the block number 00 and always has Priority 0.
The days of the week and the channels can be combined into a block as required.
A particular switching time is then assigned to this selection.
Free weekday and channel block formation
Note: Channel 2 – optionally Channel 1 – is reserved for the MDI integration times.
Example: Monday to Friday 06:00
Channel 1 ON = I; Channel 3 OFF = 0
The input mode is opened with one of the following keys: Mo … Su, h+, h-, m+, m-, I/0
All 7 days of the week are displayed. the days of the week not required can be deselected by pressing the relevant Mo … Su key.
Note:
Switching commands without date assignment (routine week program) but with weekday(s), switching time and channel state represent
a complete input and can be stored both with N and S.
Entering the data
Keys h+, h- = Enter hours for switching time
m+, m- = Enter minutes for switching time
I/0 = Enter switching state for Channels 1 and 3
Store this data with the key N or S.
If programming is interrupted for approximately 2 minutes, the display contents change back to the current time/date.
It is possible to switch to the current state at any time with the key .
9. Programming date ranges
If a program other than the routine week program is to be executed – e. g. in a vacation week – it is first necessary to enter and store the
corresponding date range.
Block number 01 is automatically assigned to this range. It receives Priority 1 and forms a part-input within this block.
It is, of course, possible to enter several date ranges.
The corresponding switching commands are then entered.
Example: Data: Keys:
Block number
14.04. to 28.04.
08:00, Channel 1 ON
Monday to Friday
?
Day, Month Day, Month
Day, Month Day, Month
Store with N
Continue switching with,
for example, h+
h+, h-, m+, m-, I/0
Sa, Su,
Store with S
Blank line
Blank line