12. Pb (lead-acid) programs
This program is designed for charging and discharging lead - sulphuric acid and lead-gel batteries with
nominal voltages of
exactly 2, 6, 12 and 24 V (1, 3, 6 and 12 cells). Caution: the charger will not recognise
lead-acid batteries with other nominal voltages, and such batteries must not be connected.
Lead-acid batteries behave entirely differently from NiCd and NiMH batteries. Lead-acid batteries can only
deliver relatively low currents relative to their capacity, and similar restrictions very definitely apply to
charging. Manufacturers usually state 14 to 16 hours for achieving nominal capacity when recharging at
the normal charge current. The “normal” charge current is defined as one tenth of the battery’s nominal
capacity. Example: battery capacity = 12 Ah —> normal charge current = 1.2 A. In contrast to NiCd and
NiMH batteries, lead-acid chargers generally monitor the battery’s voltage in order to decide when it is fully
charged.
Caution: lead-acid batteries cannot and must not be fast-charged! Always select the charge current
which the battery manufacturer recommends. Please also bear in mind that the nominal capacity (i.e.
useful life) of a lead-acid battery is very quickly compromised by incorrect handling, including overcharging,
repeated 100% discharges and, in particular, deep discharging. The magnitude of the charge / discharge
currents used is also crucial to the actual battery capacity which can be exploited, i.e. the higher the
current, the lower the capacity which can be exploited.
The values selected in the user settings for charge termination delay and safety timer have no effect in the
Pb charge programs.
Pb manual program
The battery can then be connected to the charger and the charge process started: the unit starts charging
at 0.00 A and slowly raises the current until it reaches the set limit.
The charger constantly assesses the state of the battery during the charge process, and adjusts the
charge current to suit its condition. The charge program automatically determines the number of cells (cell
count) in the battery by measuring its overall voltage.
Please do not be surprised if the charger does not deliver the charge current you have selected. The
charge program constantly monitors the battery’s voltage, and thereby limits the current in order to prevent
excessive gassing of the battery.
MODE MODE MODE MODE
Pb
AUTOMATIC-
program
Pb
MANUAL-
program
Pb
discharge
program
Pb
capacity test-
program
Pb
trickle
charge
MODE
Pb automatic program
___________ _____
___________ _____
Pb automatic
C:2.5A limited
DECINC
+
-
In this program the charger detects the types of battery
connected and adjusts the charge current accordingly, to
avoid overcharging the pack.
The maximum charge current can be set using the INC /
DEC buttons
before you connect the battery to be charged.
The charge process is terminated according to the values
set by the user for „NiCd Delta-Peak Termination Voltage“,
„Charge Termination Delay“ and „Safety Timer“.
Lithium discharge program
Lithium capacity test program
Lithium battery cell count
When you connect the battery to the charger and press the
START button, the screen displays the number of Lithium
cells. If the pack consists of 1 - 3 cells, the cell count occurs
completely automatically.
With more than 3 cells you may have to adjust the number of
cells manually using the INC/DEC buttons, as the charger
cannot reliably detect the cell count above 4 cells. In this
case the „4 cells“ display will flash. On the right-hand side of
the screen you will see the voltage of the connected battery;
this allows you to check the cell count.
Press the START button again to start the charge process.
This program determines the capacity of a Lithium battery
pack.Before actually starting the program it is essential to
check that the battery type is set correctly in the LiPo set-up
program; the settings must be adjusted if necessary.
The program initially charges the pack at the set charge
current relative to its capacity (0 … 9900 mAh), which is
shown on the left of the screen, and then discharges it at
the set discharge current (0.1 … 3.0 A) shown on the right
of the screen.The screen then displays the discharged
battery capacity.To obtain a sensible capacity display the
discharge current should be set no higher than 500 mA per
1000 mAh of battery capacity.
Note also that the set discharge current must not exceed the
maximum discharge current stated by the battery
manufacturer.Please bear in mind that excessive discharge
currents will damage the battery, and will also give a false
capacity display.
This program is designed to determine the residual capacity
of a lithium battery which is not completely discharged.
In this program the unit discharges the battery using the set
discharge current (0.1 … 3.0 A, left of screen) until it
reaches the set final discharge voltage (2.5 … 3.7 V per cell,
right of screen).
The final discharge voltage cannot be set to a value below
2.5 V per cell, as this would cause damage to the battery.
___________ _____
___________ _____
LiPo discharge
2.5A 2.5V/Cell
DECINC
+
-
DEC
INC
+
-
ENTER
___________ _____
___________ _____
LiPo capacity
C:2500mAh D:2.5A
DEC
INC
+
-
DEC
INC
+
-
ENTER
___________ _____
___________ _____
***LiPo cells**
*
4cells (15.30V
)
DEC
INC
+
-
Lithium type select program
___________ _____
___________ _____
Lithium Type
LiPo
INC
+
-
DEC
This is the most important set-up program for Lithium
batteries.In this select program you set the appropriate
battery type.This setting must be made and checked
carefully, as the charger derives all the other charge
parameters from these settings.
Setting the battery type (LiPo or LiIo) affects the charge
termination voltage. If you find that a Lithium battery has
been unexpectedly charged up to only 2/3 of full capacity,
you may have set the wrong battery type at this point.
Caution: if you set an incorrect value here, the battery may
be irreparably damaged, and could even explode!
! Caution ! Please take great care
to set the correct number of cells,
otherwise the pack may explode
and go up in flames!
___________ _____
___________ _____
Pb manual
C:2.5A
DECINC
+
-
In this program you can set the maximum permissible charge
current using the INC / DEC buttons, but only
before you
connect the lead-acid battery for charging. This setting only
determines the top limit which the charger is
permitted to feed
to the battery. If the battery manufacturer states a low maxi-
mum charge current, then it is important to limit the charge
current to that value to avoid the charger setting a higher
current if the battery appears to be willing to accept charge.
17

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Graupner Ultramat 17 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Graupner Ultramat 17

Graupner Ultramat 17 Bedienungsanleitung - Holländisch - 18 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info