Electrical test data
• Software class: A
• Contamination class: 2
Rated surge voltage: 2,500 V
The test for electromagnetic compatibility (interference emission
test) was performed at the rated voltage and rated current.
Approval and conformity
The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
Electrical installation
Electrical installation work must only be performed
by a qualified electrician. This work must be
carried out in accordance with the regulations
according to IEC 60364-7-701 (corresponding
to VDE 0100 Part 701) as well as all national and
local regulations.
Installation
Refer to the installation dimensions on fold-out page I and II,
Fig. [1].
Flush pipes thoroughly before and after installation
(observe EN 806).
Install pressure-reducing valve on service valve, see fold-
out page II, Figs. [2] to [4].
Install and connect fitting, see Figs. [5] to [7].
Important: The cable must not be pinched.
Install cooler/carbonator, see Figs. [1] and [8].
When transporting or installing the cooler/carbonator,
cooling fluid may have run into the lines. In order
to ensure that the cooling fluid has run back, the
cooler/carbonator may only be switched on following
a pause of 24 hours.
A distance of at least 50mm must be maintained around the
cooler/carbonator at all times.
Adequate ventilation must be ensured. If necessary, provide
ventilation grilles in the cover of the lower cabinet.
Install filter cartridge, see Figs. [9] to [12].
The filter head can be swivelled forwards by up to 90° in the
wall holder to install the cartridge.
The wall holder can also be fastened directly to the lower
cabinet or to the wall.
Connect cooler/carbonator, see Figs. [7] and fold-out page
III, Fig. [13] to [16].
Open hot and cold water supply and check that
connections are watertight.
Flush filter cartridge, see Fig. [17].
Press the flush button on the filter head in order to flush the
filter system. Continue flushing until the water emerging from
the hose is clear and free of bubbles (at least 2 litres).
Connect CO
2
cylinder, see Figs. [18] to [23].
Do not operate the valve on the back of the cooler/
carbonator as otherwise CO
2
will escape, see Fig. [19].
The valve is only needed when cleaning the cooler/carbonator.
Connect plug-in connector of fitting to plug-in connector
of cooler/carbonator, see Fig. [24].
Establish voltage supply via mains plug, see fold-out
page IV, Fig. [25].
The display illuminates and the remaining filter capacity is
displayed in percent.
Operation / commissioning
Open lever in order to draw hot and cold tap water, see
fold-out page IV, Fig. [26].
By turning handle, the carbon dioxide content of the cooled
and filtered water can be changed:
- Position OFF [display does not illuminate]
- Position Chilled [display illuminates blue]
= still water
- Position Medium [display illuminates turquoise]
= lightly carbonated water
- Position Sparkling [display illuminates green]
= strongly carbonated water
Control, see fold-out page IV, Fig. [27].
The buttons have the following functions:
Filter replacement reset
U Filter size selection
c Carbonate hardness adjustment
Display, see fold-out page IV, Fig. [27].
In the inactive state, the remaining filter capacity is displayed
in percent.
Display of filter capacity in handle:
The fitting has a system-related run-on time of
approx. 1 second each time carbonated water is drawn.
The display in the handle illuminates blue.
Set the temperature of the cooled, carbonated water on
the cooler/carbonator, see fold-out page IV, Fig. [27].
Set carbonate hardness at filter head, see Fig. [28].
The relevant water supplier can provide information on the
carbonate hardness.
Set carbonate hardness at bypass setting of filter head to local
conditions, see table column A on fold-out page IV.
This product conforms to the requirements of the
relevant EU guidelines.
Flashing signal Meaning
 Filter capacity of more than 10%
Filter capacity of less than 10%
Order filter cartridge
  
Filter capacity of less than 1%
Change filter cartridge soon
     
No filter capacity, Change filter
cartridge immediately
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

grohe-blue-chilled-and-sparkling-system

Suche zurücksetzen

  • Ich habe den aktivkohlefilter gewechselt und nachdem er 99 anzeigte und 12 h funktionierte, blinkt er nun rot und zeigt E1. Ich soll die Absperrventile öffnen- was bedeutet das ? Eingereicht am 14-3-2022 12:54

    Antworten Frage melden
  • Wie schließe ich den schwarzen und blauen Schlauch an? Eingereicht am 14-8-2020 18:33

    Antworten Frage melden
  • Hallo,wir haben leider die Gasflasche zu spät im Vorgang abgemacht, nun blinkt C4 im Reinigungszyklus schon lange. Geht das irgendwann weiter, oder müssen wir von vorne starten? Eingereicht am 6-10-2019 18:32

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Grohe Blue Chilled and Sparkling system wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Grohe Blue Chilled and Sparkling system

Grohe Blue Chilled and Sparkling system Installationsanweisung - Englisch - 42 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info